Customize Consent Preferences

We use cookies to help you navigate efficiently and perform certain functions. You will find detailed information about all cookies under each consent category below.

The cookies that are categorized as "Necessary" are stored on your browser as they are essential for enabling the basic functionalities of the site. ... 

Always Active

Necessary cookies are required to enable the basic features of this site, such as providing secure log-in or adjusting your consent preferences. These cookies do not store any personally identifiable data.

No cookies to display.

Functional cookies help perform certain functionalities like sharing the content of the website on social media platforms, collecting feedback, and other third-party features.

No cookies to display.

Analytical cookies are used to understand how visitors interact with the website. These cookies help provide information on metrics such as the number of visitors, bounce rate, traffic source, etc.

No cookies to display.

Performance cookies are used to understand and analyze the key performance indexes of the website which helps in delivering a better user experience for the visitors.

No cookies to display.

Advertisement cookies are used to provide visitors with customized advertisements based on the pages you visited previously and to analyze the effectiveness of the ad campaigns.

No cookies to display.

Skip to content

Hygiene monitoring system for endoscopes

SKU: KPRO2-E250 Category: Tag:

Additional information

Brand

Chemdye

Process

Hygiene Monitoring

Packaging

5

Regulations

ISO 13485:2016/NS-EN ISO 13485:2016. ISO 15883-1: 2006 / HTM 01-01: 2016 / HTM 01-05: 2013.

Field of activity

Healthcare

Description

KPRO2-E250 / Designed to detect proteins on endoscopes and other reusable instruments with hard to reach internal channels or cannulated instruments.

The first step in properly cleaning surgical instruments is to rinse off all blood, bodily fluids and tissue immediately after use. If cleaning is not carried out adequately, it may render the disinfection stage ineffective, causing patients to be exposed to body fluids and tissue contaminants from prior patients, which can result in the transmission of pathogens and affect large numbers of people.

Chemdye® KPRO2-E69 and KPRO2-E250 Hygiene Systems were designed to check cleanliness of surgical equipment by detecting protein residues after an improper cleaning. The systems have a high absorption swab, allowing the collection of samples from different surfaces with the same efficacy. The systems are compatible with cleaning verification of endoscopes and other reusable instruments with hard to reach internal channels or cannulated instruments.

For this, use the special SW250 endoscope swabs, which may be introduced through the biopsy channel of the endoscope to sample contaminants left after the cleaning process. A visual color change indicates the presence of detectable levels of protein. KPRO2-E69 and KPRO2-E250 have high sensitivity and can detect as little as 1 μg of protein.

Indications for use

1. Take a swab from the foil pouch without making contact with the absorbent part of another swab.

2. Moisturize the swab by immersing the swab tip into the moisturizer tube for 5 seconds before swabbing. Do not push the swab against the walls of the tube. Do not shake.

3. Slide the swab excessively over the surface where you want to collect the sample.

NOTE:

A) When using SW250 endoscope swabs insert the swab into the endoscope channel and push it all the way through one time. Then, cut the tip of the swab (approximately 7 cm from the end) with a pair of scissors. Be careful not to cut the distal end. Finally, pull the wire from the distal end to remove the remaining swab segment from the biopsy channel.

B) If you work under the ISO 15883 standard, it is recommended to

sample approximately 10 cm2 of surface. Swab in zigzag in one direction and then do the same perpendicularly.

Apply pressure on the swab and rotate it while collecting the sample. For performing comparable cleaning tests, you must standardize surface sampling. In order to achieve this, it is advisable to take the sample always at similar points of surface, with an invariable area of 10 cm2 , swab 10 times in each direction.

C) If you work under the HTM 01-01 standard, pick one size of the surgical instrument to be tested and swab thoroughly over its surface. Apply pressure on the swab and rotate it while collecting the sample.

4. Unscrew the cap of the vial and immerse the swab tip (or the initial segment of the endoscope swab) in the reactive colorimetric solution, move it for 15 seconds into the solution.

IMPORTANT: Do not push the swab against the walls of the tube, just immerse and move the swab into the solution. If hydration or immersion procedure was incorrect, the analysis might be affected.

5. Discard the swab and screw the cap back on the reagent vial. Color development will be complete after 1 minute and will be stable during 20 minutes.

6. Interpret results visually by using the reference guide. By comparing the color of the test against the reference guide, an estimation of the surface cleanliness can be made:

IMPORTANT: Results analyzed beyond the recommended period are not valid.

7. After using the KPRO2-E system, reprocess the instrument or the surface used for the monitoring of proteins.

Description

KPRO2-E250 / Designed to detect proteins on endoscopes and other reusable instruments with hard to reach internal channels or cannulated instruments.

The first step in properly cleaning surgical instruments is to rinse off all blood, bodily fluids and tissue immediately after use. If cleaning is not carried out adequately, it may render the disinfection stage ineffective, causing patients to be exposed to body fluids and tissue contaminants from prior patients, which can result in the transmission of pathogens and affect large numbers of people.

Chemdye® KPRO2-E69 and KPRO2-E250 Hygiene Systems were designed to check cleanliness of surgical equipment by detecting protein residues after an improper cleaning. The systems have a high absorption swab, allowing the collection of samples from different surfaces with the same efficacy. The systems are compatible with cleaning verification of endoscopes and other reusable instruments with hard to reach internal channels or cannulated instruments.

For this, use the special SW250 endoscope swabs, which may be introduced through the biopsy channel of the endoscope to sample contaminants left after the cleaning process. A visual color change indicates the presence of detectable levels of protein. KPRO2-E69 and KPRO2-E250 have high sensitivity and can detect as little as 1 μg of protein.

Indications for use

1. Take a swab from the foil pouch without making contact with the absorbent part of another swab.

2. Moisturize the swab by immersing the swab tip into the moisturizer tube for 5 seconds before swabbing. Do not push the swab against the walls of the tube. Do not shake.

3. Slide the swab excessively over the surface where you want to collect the sample.

NOTE:

A) When using SW250 endoscope swabs insert the swab into the endoscope channel and push it all the way through one time. Then, cut the tip of the swab (approximately 7 cm from the end) with a pair of scissors. Be careful not to cut the distal end. Finally, pull the wire from the distal end to remove the remaining swab segment from the biopsy channel.

B) If you work under the ISO 15883 standard, it is recommended to

sample approximately 10 cm2 of surface. Swab in zigzag in one direction and then do the same perpendicularly.

Apply pressure on the swab and rotate it while collecting the sample. For performing comparable cleaning tests, you must standardize surface sampling. In order to achieve this, it is advisable to take the sample always at similar points of surface, with an invariable area of 10 cm2 , swab 10 times in each direction.

C) If you work under the HTM 01-01 standard, pick one size of the surgical instrument to be tested and swab thoroughly over its surface. Apply pressure on the swab and rotate it while collecting the sample.

4. Unscrew the cap of the vial and immerse the swab tip (or the initial segment of the endoscope swab) in the reactive colorimetric solution, move it for 15 seconds into the solution.

IMPORTANT: Do not push the swab against the walls of the tube, just immerse and move the swab into the solution. If hydration or immersion procedure was incorrect, the analysis might be affected.

5. Discard the swab and screw the cap back on the reagent vial. Color development will be complete after 1 minute and will be stable during 20 minutes.

6. Interpret results visually by using the reference guide. By comparing the color of the test against the reference guide, an estimation of the surface cleanliness can be made:

IMPORTANT: Results analyzed beyond the recommended period are not valid.

7. After using the KPRO2-E system, reprocess the instrument or the surface used for the monitoring of proteins.

Related Products

SWE-1.7

High absorcion swabs Chemdye® for use with PRO1 ENDO

PRO1 ENDO

Hygiene Monitoring System For protein detection and quantification on cannulated instruments

KPRO2-E69

Hygiene monitoring system for detecting residual protein on surfaces

Moisturizer

Mostuirizing solution for protein pen system