7min Helix kit for steam (plastic)
Additional information
Brand | Chemdye |
---|---|
Process | Steam |
Packaging | 1 plastic device + 1 cotton bag + 250 strips |
Initial Color | Yellow |
Final Color | Black |
Indicator Type | Type 2 Chemical Indicator |
Regulations | EN 867-5, ISO 11140-1 |
Field of activity | Dental, Healthcare |
Description
KH2X15-7.0Y/P / Helix-PCD + Test strips Kit for Steam sterilization processes 7 min.134° C. Load release. Plastic capsule. Plastic tube of 1,5 m and 2 mm internal diameter. 1 cotton bag + 250 strips PCD-A-7.0Y Turns from Yellow to Black. EN 867-5, ISO 11140-1 Type 2.
Process Challenge Device for Steam sterilization processes control. For safe release hollow loads. Conditions: 7 minutes, 134ºC // 20 minutes, 121 °C.
Characteristics
Helix-PCD
Plastic capsule of great resistance and durability, to hold a Chemical Indicator designed for this system. The capsule is connected to a high resistance plastic tube of 1.5 m length (see catalogue for other lengths) and 2 mm internal diameter. Special silicone connector coated by external connector.
PCD-A-7.0Y
Type 2 Chemical Indicator.
Self-adhesive strip printed with indicator ink. Size: 76 x 6 mm.
10 strips per sheet. Size: 80 x 98.5 mm.
Initial color: yellow
Final color: dark brown/black
Authorization: ANMAT (Argentinean National Administration of Drugs, Food and Medical Devices) PM-1614-4.
NOTE: If the 4 bars change to the final color, the sterilization cycle was successful, the load can be securely released. If one or more bars did not turn to the final color, this shows a failure in sterilizing agent penetration, the load cannot be considered sterile, that is, it cannot be released.
100 % Toxic Heavy Metals free.
Description
KH2X15-7.0Y/P / Helix-PCD + Test strips Kit for Steam sterilization processes 7 min.134° C. Load release. Plastic capsule. Plastic tube of 1,5 m and 2 mm internal diameter. 1 cotton bag + 250 strips PCD-A-7.0Y Turns from Yellow to Black. EN 867-5, ISO 11140-1 Type 2.
Process Challenge Device for Steam sterilization processes control. For safe release hollow loads. Conditions: 7 minutes, 134ºC // 20 minutes, 121 °C.
Characteristics
Helix-PCD
Plastic capsule of great resistance and durability, to hold a Chemical Indicator designed for this system. The capsule is connected to a high resistance plastic tube of 1.5 m length (see catalogue for other lengths) and 2 mm internal diameter. Special silicone connector coated by external connector.
PCD-A-7.0Y
Type 2 Chemical Indicator.
Self-adhesive strip printed with indicator ink. Size: 76 x 6 mm.
10 strips per sheet. Size: 80 x 98.5 mm.
Initial color: yellow
Final color: dark brown/black
Authorization: ANMAT (Argentinean National Administration of Drugs, Food and Medical Devices) PM-1614-4.
NOTE: If the 4 bars change to the final color, the sterilization cycle was successful, the load can be securely released. If one or more bars did not turn to the final color, this shows a failure in sterilizing agent penetration, the load cannot be considered sterile, that is, it cannot be released.
100 % Toxic Heavy Metals free.