3.5min Helix kit for steam (plastic)

SKU: KH2X15-3.5Y/P Category: Tag:

Additional information

Brand

Chemdye

Process

Steam

Packaging

1 metallic device + 1 cotton bag + 250 strips

Initial Color

Yellow

Final Color

Black

Indicator Type

Type 2 Chemical Indicator

Regulations

EN 867-5, ISO 11140-1

Field of activity

Dental, Healthcare

Description

KH2X15-3.5Y/P / Helix-PCD + Test strips Kit for Steam sterilization processes: 3,5 min.134° C. Load release. Plastic capsule. Plastic tube of 1,5 m and 2 mm internal diameter. 1 cotton bag + 250 strips PCD-A-3.5Y Turns from Yellow to Black. EN 867-5, ISO 11140-1 Type 2.

Process Challenge Device for Steam sterilization processes control. For safe release of hollow loads. Conditions: 3.5 min at 134 ºC.

Characteristics

Helix-PCD Plastic capsule of great resistance and durability, to hold a Chemical Indicator designed for this system. The capsule is connected to a high resistance plastic tube of 1.5 m length (see catalogue for other lengths) and 2 mm internal diameter. Special silicone connector coated by external connector.

PCD-A-3.5Y

Type 2 Chemical Indicator.

Self-adhesive strip printed with indicator ink. Size: 76 x 6 mm.

10 strips per sheet. Size: 80 x 98.5 mm.

Initial color: yellow

Final color: dark brown/black

Authorization: ANMAT (Argentinean National Administration of Drugs, Food and Medical Devices) PM-1614-4.

NOTE: If the 4 bars change to the final color, the sterilization cycle was successful, the load can be securely released. If one or more bars did not turn to the final color, this shows a failure in sterilizing agent penetration, the load cannot be considered sterile, that is, it cannot be released.

100 % Toxic Heavy Metals free.

Description

KH2X15-3.5Y/P / Helix-PCD + Test strips Kit for Steam sterilization processes: 3,5 min.134° C. Load release. Plastic capsule. Plastic tube of 1,5 m and 2 mm internal diameter. 1 cotton bag + 250 strips PCD-A-3.5Y Turns from Yellow to Black. EN 867-5, ISO 11140-1 Type 2.

Process Challenge Device for Steam sterilization processes control. For safe release of hollow loads. Conditions: 3.5 min at 134 ºC.

Characteristics

Helix-PCD Plastic capsule of great resistance and durability, to hold a Chemical Indicator designed for this system. The capsule is connected to a high resistance plastic tube of 1.5 m length (see catalogue for other lengths) and 2 mm internal diameter. Special silicone connector coated by external connector.

PCD-A-3.5Y

Type 2 Chemical Indicator.

Self-adhesive strip printed with indicator ink. Size: 76 x 6 mm.

10 strips per sheet. Size: 80 x 98.5 mm.

Initial color: yellow

Final color: dark brown/black

Authorization: ANMAT (Argentinean National Administration of Drugs, Food and Medical Devices) PM-1614-4.

NOTE: If the 4 bars change to the final color, the sterilization cycle was successful, the load can be securely released. If one or more bars did not turn to the final color, this shows a failure in sterilizing agent penetration, the load cannot be considered sterile, that is, it cannot be released.

100 % Toxic Heavy Metals free.