Helix kit w/ test strips for LTSF
Additional information
Brand | Chemdye |
---|---|
Process | Formaldehyde |
Packaging | 1 plastic device + 1 cotton bag + 250 strips |
Initial Color | Bordeaux |
Final Color | Green |
Indicator Type | Type 2 Chemical Indicator |
Regulations | EN 14180, EN 867-5 |
Field of activity | Healthcare |
Description
KH2X15-F1/P / Helix-PCD + Test strips Kit for Formaldehyde sterilization processes. Plastic capsule. Plastic tube of ( 1,5 m, 2 mm internal diameter ) + 250 strips PCD-A-F1. Turns from Bordeaux to Green. EN 867-5, ISO 11140-1Type 2.
Kit for control of Formaldehyde sterilization processes. For safe release of hollow loads. Condition: for LTSF processes.
Characteristics
Helix-PCD
Plastic capsule of great resistance and durability, to hold a Chemical Indicator designed for this system. The capsule is connected to a high resistance plastic tube of 1.5 m length (see catalogue for other lengths) and 2 mm internal diameter. Special silicone connector coated by external connector.
PCD-A-F1
Type 2 Chemical Indicator.
Self-adhesive strip printed with indicator ink. Size: 76 x 6 mm.
10 strips per sheet. Size: 80 x 98.5 mm.
Initial color: bordeaux
Final color: green
Authorization: ANMAT (Argentinean National Administration of Drugs, Food and Medical Devices) PM 1614-4.
NOTE: If 4 bars change to the final color, the result is successful, the sterilizer works properly. If one or more bars have not turned to the final color, this shows a failure in sterilizing agent penetration, therefore an equipment malfunction.
100 % Toxic Heavy Metals free.
Description
KH2X15-F1/P / Helix-PCD + Test strips Kit for Formaldehyde sterilization processes. Plastic capsule. Plastic tube of ( 1,5 m, 2 mm internal diameter ) + 250 strips PCD-A-F1. Turns from Bordeaux to Green. EN 867-5, ISO 11140-1Type 2.
Kit for control of Formaldehyde sterilization processes. For safe release of hollow loads. Condition: for LTSF processes.
Characteristics
Helix-PCD
Plastic capsule of great resistance and durability, to hold a Chemical Indicator designed for this system. The capsule is connected to a high resistance plastic tube of 1.5 m length (see catalogue for other lengths) and 2 mm internal diameter. Special silicone connector coated by external connector.
PCD-A-F1
Type 2 Chemical Indicator.
Self-adhesive strip printed with indicator ink. Size: 76 x 6 mm.
10 strips per sheet. Size: 80 x 98.5 mm.
Initial color: bordeaux
Final color: green
Authorization: ANMAT (Argentinean National Administration of Drugs, Food and Medical Devices) PM 1614-4.
NOTE: If 4 bars change to the final color, the result is successful, the sterilizer works properly. If one or more bars have not turned to the final color, this shows a failure in sterilizing agent penetration, therefore an equipment malfunction.
100 % Toxic Heavy Metals free.