Skip to content

Lumenia Six Flow Cleaning Challenge Kit for 6-channel endoscope reprocessors

Additional information
Brand

Chemdye

Process

Endoscope Reprocessing

Packaging

1 Challenge Device + 720 cleaning indicators + 1 plastic tweezer + 6 blockage test capsules

Initial Color

Fuchsia

Final Color

No Color

Regulations

ISO 13485, ISO 15883-4, ISO/TS 15883-5

Field of activity

Healthcare

Description

LSF1 / Challenge Kit designed for monitoring the effectiveness of cleaning performance of flexible endoscopes in 6-channels Automatic Endoscope Reprocessors.

Challenge Kit designed for monitoring the effectiveness of cleaning performance of flexible endoscopes in Automatic Endoscope Reprocessors.

Characteristics

Challenge Device

Chemdye® Lumenia SixFlow LSF1 Test Kit consists of a challenge device (Chemdye® Lumenia SixFlow CCDER61) and cleaning indicators (Chemdye® Lumenia CDWE) for monitoring cleaning performance in Automated Endoscope Reprocessors.

The challenge device consists of three polytetrafluoroethylene (PTFE) tubes with an inner diameter of 1 mm, two PTFE tubes with an inner diameter of 2 mm, and a PTFE tube with an inner diameter of 4 mm, all of them 1.5 m long. Each tube has special connectors in one of its ends for plugging it to the Endoscope Reprocessor and a device in the other end that simulates an endoscope´s lumen and where the Chemdye® Lumenia CDWE cleaning indicators are placed (one in the inner cavity of the device and the other one in an external slot).

Each of the six devices have different colors that match the channels€™ diameters to be monitored, and are in line with the color scheme that every Reprocessor Machine has in its output terminals. The end of each PTFE tube opposite to that one connected to the device is identified with a colored mark, allowing a fast recognition of the output terminal to which it will be connected. The tubes are joined and protected through a hose that covers them entirely.

Cleaning indicator

Chemdye® Lumenia CDWE cleaning indicator was especially designed for monitoring the performance of cleaning processes. It consists of a test soil, developed in accordance with the requirements described in ISO/TS 15883-5:2005 standard, arranged on a self-adhesive thermolabile synthetic support. The formulation of the cleaning indicator allows the detection of factors that affect the result of the cleaning process.

Size of the indicator strip: 38 mm x 6 mm.

Initial condition: fuchsia color.

Final condition: total elimination of the fuchsia organic substance.

The indicator€™s ink is not toxic.

Description

LSF1 / Challenge Kit designed for monitoring the effectiveness of cleaning performance of flexible endoscopes in 6-channels Automatic Endoscope Reprocessors.

Challenge Kit designed for monitoring the effectiveness of cleaning performance of flexible endoscopes in Automatic Endoscope Reprocessors.

Characteristics

Challenge Device

Chemdye® Lumenia SixFlow LSF1 Test Kit consists of a challenge device (Chemdye® Lumenia SixFlow CCDER61) and cleaning indicators (Chemdye® Lumenia CDWE) for monitoring cleaning performance in Automated Endoscope Reprocessors.

The challenge device consists of three polytetrafluoroethylene (PTFE) tubes with an inner diameter of 1 mm, two PTFE tubes with an inner diameter of 2 mm, and a PTFE tube with an inner diameter of 4 mm, all of them 1.5 m long. Each tube has special connectors in one of its ends for plugging it to the Endoscope Reprocessor and a device in the other end that simulates an endoscope´s lumen and where the Chemdye® Lumenia CDWE cleaning indicators are placed (one in the inner cavity of the device and the other one in an external slot).

Each of the six devices have different colors that match the channels€™ diameters to be monitored, and are in line with the color scheme that every Reprocessor Machine has in its output terminals. The end of each PTFE tube opposite to that one connected to the device is identified with a colored mark, allowing a fast recognition of the output terminal to which it will be connected. The tubes are joined and protected through a hose that covers them entirely.

Cleaning indicator

Chemdye® Lumenia CDWE cleaning indicator was especially designed for monitoring the performance of cleaning processes. It consists of a test soil, developed in accordance with the requirements described in ISO/TS 15883-5:2005 standard, arranged on a self-adhesive thermolabile synthetic support. The formulation of the cleaning indicator allows the detection of factors that affect the result of the cleaning process.

Size of the indicator strip: 38 mm x 6 mm.

Initial condition: fuchsia color.

Final condition: total elimination of the fuchsia organic substance.

The indicator€™s ink is not toxic.

Category
Select some options
Category
Process
Select some options
Process
Field of Activity
Field of Activity
Brand
Select some options
Brand
Read-Out Time
Select some options
Read-Out Time