<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>Protein Pens - Terragene</title>
	<atom:link href="https://terragene.com/product-category/protein-pens/feed/" rel="self" type="application/rss+xml" />
	<link>https://terragene.com</link>
	<description>Biotechnology Company</description>
	<lastBuildDate>Fri, 06 Mar 2026 17:22:01 +0000</lastBuildDate>
	<language>en</language>
	<sy:updatePeriod>
	hourly	</sy:updatePeriod>
	<sy:updateFrequency>
	1	</sy:updateFrequency>
	<generator>https://wordpress.org/?v=6.9.4</generator>

<image>
	<url>https://terragene.com/wp-content/uploads/2020/12/cropped-FAVICON-TERRAGENE-AZUL-Rev.1-32x32.png</url>
	<title>Protein Pens - Terragene</title>
	<link>https://terragene.com</link>
	<width>32</width>
	<height>32</height>
</image> 
	<item>
		<title>PRO1 ENDO – Protein Detection and Quantification on Cannulated Instruments</title>
		<link>https://terragene.com/product/hygiene-monitoring-system-for-protein-detection-and-quantification-on-cannulated-instruments/</link>
					<comments>https://terragene.com/product/hygiene-monitoring-system-for-protein-detection-and-quantification-on-cannulated-instruments/#respond</comments>
		
		<dc:creator><![CDATA[Agustin Alvarez]]></dc:creator>
		<pubDate>Thu, 21 Nov 2024 12:59:37 +0000</pubDate>
				<guid isPermaLink="false">https://terragene.com/?post_type=product&#038;p=39295</guid>

					<description><![CDATA[<p>The first step in proper cleaning of surgical instruments is to remove blood, body fluids, and tissues immediately after use. If cleaning is not performed<br />
properly, the disinfection/sterilization steps will not be effective, leading to the exposure of patients to contaminants such as body fluids, tissues from other patients, and microorganisms.</p>
<p>The Chemdye® PRO 1 ENDO Hygiene Monitoring System is designed to verify the cleanliness of cannulated instruments by detecting protein residues that may remain after the cleaning process. The system is used in conjunction with Chemdye® SWE high absorption swabs, specially designed for cannulated instruments. These swabs must be inserted through the internal<br />
channel of the cannulae to sample for contaminants that may remain after the cleaning process.</p>
<p>The Chemdye® PRO1 ENDO system provides quantitative results in the range of 1 to 50 μg of protein with a limit of detection (LOD) of 0.5 μg*, when incubated in the recommended Bionova® Auto-readers.</p>
<p><em>*Refers to µg BSA (bovine serum albumin).</em></p>
<p>The post <a href="https://terragene.com/product/hygiene-monitoring-system-for-protein-detection-and-quantification-on-cannulated-instruments/">PRO1 ENDO – Protein Detection and Quantification on Cannulated Instruments</a> first appeared on <a href="https://terragene.com">Terragene</a>.</p>]]></description>
										<content:encoded><![CDATA[<p>The first step in proper cleaning of surgical instruments is to remove blood, body fluids, and tissues immediately after use. If cleaning is not performed<br />
properly, the disinfection/sterilization steps will not be effective, leading to the exposure of patients to contaminants such as body fluids, tissues from other patients, and microorganisms.</p>
<p>The Chemdye® PRO 1 ENDO Hygiene Monitoring System is designed to verify the cleanliness of cannulated instruments by detecting protein residues that may remain after the cleaning process. The system is used in conjunction with Chemdye® SWE high absorption swabs, specially designed for cannulated instruments. These swabs must be inserted through the internal<br />
channel of the cannulae to sample for contaminants that may remain after the cleaning process.</p>
<p>The Chemdye® PRO1 ENDO system provides quantitative results in the range of 1 to 50 μg of protein with a limit of detection (LOD) of 0.5 μg*, when incubated in the recommended Bionova® Auto-readers.</p>
<p><em>*Refers to µg BSA (bovine serum albumin).</em></p>
<p>The post <a href="https://terragene.com/product/hygiene-monitoring-system-for-protein-detection-and-quantification-on-cannulated-instruments/">PRO1 ENDO – Protein Detection and Quantification on Cannulated Instruments</a> first appeared on <a href="https://terragene.com">Terragene</a>.</p>]]></content:encoded>
					
					<wfw:commentRss>https://terragene.com/product/hygiene-monitoring-system-for-protein-detection-and-quantification-on-cannulated-instruments/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
			</item>
		<item>
		<title>High sensitivity pen system for quantification of surface proteins</title>
		<link>https://terragene.com/product/high-sensitivity-pen-system-for-quantification-of-surface-proteins/</link>
		
		<dc:creator><![CDATA[Agustin Alvarez]]></dc:creator>
		<pubDate>Tue, 27 Aug 2024 13:25:58 +0000</pubDate>
				<guid isPermaLink="false">https://uvcindicators.com/products/high-sensitivity-pen-system-for-quantification-of-surface-proteins/</guid>

					<description><![CDATA[<p>PRO1 MICRO / High sensitivity pen system designed to detect and quantify proteins with high sensitivity on surfaces and difficult-to-access areas after the cleaning process.</p>
<p><strong>Characteristics</strong></p>
<p>-The system consists of a reactive solution and a high absorption swab, which allows the collection of samples from different types of surfaces with the same efficiency.</p>
<p>-Pen diameter: 12.4 mm; Pen length: 161 mm; Swab length: 111.9 mm.</p>
<p>-Limit of quantification: 1.0 µg of BSA.</p>
<p>-Sensitivity: 0.3 Î¼g of BSA.</p>
<p>-Qualitative analysis: Incubate using the Bionova® IC10/20 incubator (temperature: 60± 2 º°C; 7 minutes) and interpret visually by using the reference guide available inside the product€™s box.</p>
<p>-Quantitative analysis: Using the Bionova® IC10/20FR, Bionova® IC10/20FRLCD or Bionova® MiniPro auto-reader incubators. Read the instructions for use of the device previously.</p>
<p>Incubation time: using the Bionova® IC10/20FR or the Bionova® IC10/20FRLCD auto-reader incubators: 7 minutes; using the Bionova® MiniPro auto-reader incubators: 4 minutes. Incubation range: 60± 2 °C.</p>
<p>Do not open until use. Do not reuse. Do not touch the swab or the inside of the device with your hands. Wear gloves, surgical mask and other hygiene measures.</p>
<p>Do not freeze. High concentrations of alkaline detergents may cause false negative results in some cases. Hydrogen peroxide-based disinfectants may cause a false positive color change reaction.</p>
<p>Although Chemdye® PRO1 MICRO has high sensitivity, it is not a microbiological monitoring device, and the surfaces should not be considered sterile according to the results obtained.</p>
<p>The post <a href="https://terragene.com/product/high-sensitivity-pen-system-for-quantification-of-surface-proteins/">High sensitivity pen system for quantification of surface proteins</a> first appeared on <a href="https://terragene.com">Terragene</a>.</p>]]></description>
										<content:encoded><![CDATA[<p>PRO1 MICRO / High sensitivity pen system designed to detect and quantify proteins with high sensitivity on surfaces and difficult-to-access areas after the cleaning process.</p>
<p><strong>Characteristics</strong></p>
<p>-The system consists of a reactive solution and a high absorption swab, which allows the collection of samples from different types of surfaces with the same efficiency.</p>
<p>-Pen diameter: 12.4 mm; Pen length: 161 mm; Swab length: 111.9 mm.</p>
<p>-Limit of quantification: 1.0 µg of BSA.</p>
<p>-Sensitivity: 0.3 Î¼g of BSA.</p>
<p>-Qualitative analysis: Incubate using the Bionova® IC10/20 incubator (temperature: 60± 2 º°C; 7 minutes) and interpret visually by using the reference guide available inside the product€™s box.</p>
<p>-Quantitative analysis: Using the Bionova® IC10/20FR, Bionova® IC10/20FRLCD or Bionova® MiniPro auto-reader incubators. Read the instructions for use of the device previously.</p>
<p>Incubation time: using the Bionova® IC10/20FR or the Bionova® IC10/20FRLCD auto-reader incubators: 7 minutes; using the Bionova® MiniPro auto-reader incubators: 4 minutes. Incubation range: 60± 2 °C.</p>
<p>Do not open until use. Do not reuse. Do not touch the swab or the inside of the device with your hands. Wear gloves, surgical mask and other hygiene measures.</p>
<p>Do not freeze. High concentrations of alkaline detergents may cause false negative results in some cases. Hydrogen peroxide-based disinfectants may cause a false positive color change reaction.</p>
<p>Although Chemdye® PRO1 MICRO has high sensitivity, it is not a microbiological monitoring device, and the surfaces should not be considered sterile according to the results obtained.</p>
<p>The post <a href="https://terragene.com/product/high-sensitivity-pen-system-for-quantification-of-surface-proteins/">High sensitivity pen system for quantification of surface proteins</a> first appeared on <a href="https://terragene.com">Terragene</a>.</p>]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>High absorption swabs Chemdye® for use with PRO1 ENDO</title>
		<link>https://terragene.com/product/swe-3-hygiene-indicator-chemdye-for-use-with-pro-1-endo/</link>
					<comments>https://terragene.com/product/swe-3-hygiene-indicator-chemdye-for-use-with-pro-1-endo/#respond</comments>
		
		<dc:creator><![CDATA[infraestructura]]></dc:creator>
		<pubDate>Fri, 14 Mar 2025 20:00:27 +0000</pubDate>
				<guid isPermaLink="false">https://terragene.com/?post_type=product&#038;p=48419</guid>

					<description><![CDATA[<p><b>Usage</b><br />
Chemdye® SWE high-absorption swabs have been specifically designed for use with cannulated instruments. These swabs must be inserted through the internal channel of the cannula, allowing the collection of contaminants that may persist after the cleaning process. SWE swabs are designed for use with Chemdye® PRO 1 ENDO system, enabling the verification of the cleaning efficacy of cannulated instruments by detecting and quantifying protein residues that may remain after the cleaning process.</p>
<p><b>Characteristics</b><br />
Length: 2.5 m.<br />
Diameter: 3.0 mm.<br />
Recommended swab diameter:</p>
<p><img class="alignnone size-medium wp-image-48416" src="https://terragene.com/wp-content/uploads/dimentions_details_grid-300x85.png" alt="dimentions_details" width="300" height="85" /></p>
<p><b>Storage conditions</b><br />
Chemdye® SWE swabs should be stored at temperatures between 15-30 °C, protected from light and relative humidity (RH) of 20-80 %.</p>
<p><b>Transport conditions</b><br />
It is recommended to respect storage conditions during transport. Transport in closed and strengthened boxes in order to avoid damages. The transport of this product does not represent a risk for health.</p>
<p><b>Shelf life</b><br />
24 months when stored at the declared temperatures.</p>
<p><b>Packaging</b><br />
Box with 5 units.<br />
Packaging information: product code and description, presentation, storage conditions, manufacturer information and data on label.</p>
<p><b>Labelling</b><br />
On product’s box: product code, batch number, manufacture and expiration date, bar code and datamatrix code.<br />
<b>Possible target markets</b><br />
Healthcare, Pharmaceutical and Medical industries.</p>
<p><b>Other important information</b><br />
Read product’s instructions for use thoroughly before use.</p>
<p><b>Precautions</b><br />
Handle with gloves at all times.<br />
Do not open until use.<br />
Do not reuse.<br />
Do not re-incubate.<br />
Do not swab surfaces that have not been subjected to a cleaning process or visibly contaminated areas. Avoid touching the absorbent part of the swab or the inside of the device with your hands. Use gloves, a mask and other hygiene measures.<br />
Do not freeze.<br />
Do not use Chemdye® SWE swabs on any device other than</p>
<p>Chemdye® PRO 1 ENDO.<br />
High concentrations of alkaline detergents may cause false-negative results in some cases. Oxidizing disinfectants (such as hydrogen peroxide or peracetic acid) may cause a false-positive color change reaction. Although Chemdye® PRO 1 ENDO has high sensitivity, its intended use corresponds to the monitoring of channels after the cleaning process, so the test result is not evidence that the device is sterile.</p>
<p>The post <a href="https://terragene.com/product/swe-3-hygiene-indicator-chemdye-for-use-with-pro-1-endo/">High absorption swabs Chemdye® for use with PRO1 ENDO</a> first appeared on <a href="https://terragene.com">Terragene</a>.</p>]]></description>
										<content:encoded><![CDATA[<p><b>Usage</b><br />
Chemdye® SWE high-absorption swabs have been specifically designed for use with cannulated instruments. These swabs must be inserted through the internal channel of the cannula, allowing the collection of contaminants that may persist after the cleaning process. SWE swabs are designed for use with Chemdye® PRO 1 ENDO system, enabling the verification of the cleaning efficacy of cannulated instruments by detecting and quantifying protein residues that may remain after the cleaning process.</p>
<p><b>Characteristics</b><br />
Length: 2.5 m.<br />
Diameter: 3.0 mm.<br />
Recommended swab diameter:</p>
<p><img class="alignnone size-medium wp-image-48416" src="https://terragene.com/wp-content/uploads/dimentions_details_grid-300x85.png" alt="dimentions_details" width="300" height="85" /></p>
<p><b>Storage conditions</b><br />
Chemdye® SWE swabs should be stored at temperatures between 15-30 °C, protected from light and relative humidity (RH) of 20-80 %.</p>
<p><b>Transport conditions</b><br />
It is recommended to respect storage conditions during transport. Transport in closed and strengthened boxes in order to avoid damages. The transport of this product does not represent a risk for health.</p>
<p><b>Shelf life</b><br />
24 months when stored at the declared temperatures.</p>
<p><b>Packaging</b><br />
Box with 5 units.<br />
Packaging information: product code and description, presentation, storage conditions, manufacturer information and data on label.</p>
<p><b>Labelling</b><br />
On product’s box: product code, batch number, manufacture and expiration date, bar code and datamatrix code.<br />
<b>Possible target markets</b><br />
Healthcare, Pharmaceutical and Medical industries.</p>
<p><b>Other important information</b><br />
Read product’s instructions for use thoroughly before use.</p>
<p><b>Precautions</b><br />
Handle with gloves at all times.<br />
Do not open until use.<br />
Do not reuse.<br />
Do not re-incubate.<br />
Do not swab surfaces that have not been subjected to a cleaning process or visibly contaminated areas. Avoid touching the absorbent part of the swab or the inside of the device with your hands. Use gloves, a mask and other hygiene measures.<br />
Do not freeze.<br />
Do not use Chemdye® SWE swabs on any device other than</p>
<p>Chemdye® PRO 1 ENDO.<br />
High concentrations of alkaline detergents may cause false-negative results in some cases. Oxidizing disinfectants (such as hydrogen peroxide or peracetic acid) may cause a false-positive color change reaction. Although Chemdye® PRO 1 ENDO has high sensitivity, its intended use corresponds to the monitoring of channels after the cleaning process, so the test result is not evidence that the device is sterile.</p>
<p>The post <a href="https://terragene.com/product/swe-3-hygiene-indicator-chemdye-for-use-with-pro-1-endo/">High absorption swabs Chemdye® for use with PRO1 ENDO</a> first appeared on <a href="https://terragene.com">Terragene</a>.</p>]]></content:encoded>
					
					<wfw:commentRss>https://terragene.com/product/swe-3-hygiene-indicator-chemdye-for-use-with-pro-1-endo/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
			</item>
		<item>
		<title>High absorption swabs Chemdye® for use with PRO1 ENDO</title>
		<link>https://terragene.com/product/swe-2-7-hygiene-indicator-chemdye-for-use-with-pro-1-endo/</link>
					<comments>https://terragene.com/product/swe-2-7-hygiene-indicator-chemdye-for-use-with-pro-1-endo/#respond</comments>
		
		<dc:creator><![CDATA[infraestructura]]></dc:creator>
		<pubDate>Fri, 14 Mar 2025 19:33:08 +0000</pubDate>
				<guid isPermaLink="false">https://terragene.com/?post_type=product&#038;p=48410</guid>

					<description><![CDATA[<p><b>Usage</b><br />
Chemdye® SWE high-absorption swabs have been specifically designed for use with cannulated instruments. These swabs must be inserted through the internal channel of the cannula, allowing the collection of contaminants that may persist after the cleaning process. SWE swabs are designed for use with Chemdye® PRO 1 ENDO system, enabling the verification of the cleaning efficacy of cannulated instruments by detecting and quantifying protein residues that may remain after the cleaning process.</p>
<p><b>Characteristics</b><br />
Length: 2.5 m.<br />
Diameter: 2.7 mm.<br />
Recommended swab diameter:</p>
<p><img class="alignnone size-medium wp-image-48416" src="https://terragene.com/wp-content/uploads/dimentions_details_grid-300x85.png" alt="dimentions_details" width="300" height="85" /></p>
<p><b>Storage conditions</b><br />
Chemdye® SWE swabs should be stored at temperatures between 15-30 °C, protected from light and relative humidity (RH) of 20-80 %.</p>
<p><b>Transport conditions</b><br />
It is recommended to respect storage conditions during transport. Transport in closed and strengthened boxes in order to avoid damages. The transport of this product does not represent a risk for health.</p>
<p><b>Shelf life</b><br />
24 months when stored at the declared temperatures.</p>
<p><b>Packaging</b><br />
Box with 5 units.<br />
Packaging information: product code and description, presentation, storage conditions, manufacturer information and data on label.</p>
<p><b>Labelling</b><br />
On product’s box: product code, batch number, manufacture and expiration date, bar code and datamatrix code.</p>
<p><b>Possible target markets</b><br />
Healthcare, Pharmaceutical and Medical industries.</p>
<p><b>Other important information</b><br />
Read product’s instructions for use thoroughly before use.</p>
<p><b>Precautions</b><br />
Handle with gloves at all times.<br />
Do not open until use.<br />
Do not reuse.<br />
Do not re-incubate.<br />
Do not swab surfaces that have not been subjected to a cleaning<br />
process or visibly contaminated areas.<br />
Avoid touching the absorbent part of the swab or the inside of the<br />
device with your hands.<br />
Use gloves, a mask and other hygiene measures.<br />
Do not freeze.<br />
Do not use Chemdye® SWE swabs on any device other than</p>
<p>Chemdye® PRO 1 ENDO.<br />
High concentrations of alkaline detergents may cause false-negative results in some cases. Oxidizing disinfectants (such as hydrogen peroxide or peracetic acid) may cause a false-positive color change reaction. Although Chemdye® PRO1 ENDO has high sensitivity, its intended use corresponds to the monitoring of channels after the cleaning process, so the test result is not evidence that the device is sterile.</p>
<p>The post <a href="https://terragene.com/product/swe-2-7-hygiene-indicator-chemdye-for-use-with-pro-1-endo/">High absorption swabs Chemdye® for use with PRO1 ENDO</a> first appeared on <a href="https://terragene.com">Terragene</a>.</p>]]></description>
										<content:encoded><![CDATA[<p><b>Usage</b><br />
Chemdye® SWE high-absorption swabs have been specifically designed for use with cannulated instruments. These swabs must be inserted through the internal channel of the cannula, allowing the collection of contaminants that may persist after the cleaning process. SWE swabs are designed for use with Chemdye® PRO 1 ENDO system, enabling the verification of the cleaning efficacy of cannulated instruments by detecting and quantifying protein residues that may remain after the cleaning process.</p>
<p><b>Characteristics</b><br />
Length: 2.5 m.<br />
Diameter: 2.7 mm.<br />
Recommended swab diameter:</p>
<p><img class="alignnone size-medium wp-image-48416" src="https://terragene.com/wp-content/uploads/dimentions_details_grid-300x85.png" alt="dimentions_details" width="300" height="85" /></p>
<p><b>Storage conditions</b><br />
Chemdye® SWE swabs should be stored at temperatures between 15-30 °C, protected from light and relative humidity (RH) of 20-80 %.</p>
<p><b>Transport conditions</b><br />
It is recommended to respect storage conditions during transport. Transport in closed and strengthened boxes in order to avoid damages. The transport of this product does not represent a risk for health.</p>
<p><b>Shelf life</b><br />
24 months when stored at the declared temperatures.</p>
<p><b>Packaging</b><br />
Box with 5 units.<br />
Packaging information: product code and description, presentation, storage conditions, manufacturer information and data on label.</p>
<p><b>Labelling</b><br />
On product’s box: product code, batch number, manufacture and expiration date, bar code and datamatrix code.</p>
<p><b>Possible target markets</b><br />
Healthcare, Pharmaceutical and Medical industries.</p>
<p><b>Other important information</b><br />
Read product’s instructions for use thoroughly before use.</p>
<p><b>Precautions</b><br />
Handle with gloves at all times.<br />
Do not open until use.<br />
Do not reuse.<br />
Do not re-incubate.<br />
Do not swab surfaces that have not been subjected to a cleaning<br />
process or visibly contaminated areas.<br />
Avoid touching the absorbent part of the swab or the inside of the<br />
device with your hands.<br />
Use gloves, a mask and other hygiene measures.<br />
Do not freeze.<br />
Do not use Chemdye® SWE swabs on any device other than</p>
<p>Chemdye® PRO 1 ENDO.<br />
High concentrations of alkaline detergents may cause false-negative results in some cases. Oxidizing disinfectants (such as hydrogen peroxide or peracetic acid) may cause a false-positive color change reaction. Although Chemdye® PRO1 ENDO has high sensitivity, its intended use corresponds to the monitoring of channels after the cleaning process, so the test result is not evidence that the device is sterile.</p>
<p>The post <a href="https://terragene.com/product/swe-2-7-hygiene-indicator-chemdye-for-use-with-pro-1-endo/">High absorption swabs Chemdye® for use with PRO1 ENDO</a> first appeared on <a href="https://terragene.com">Terragene</a>.</p>]]></content:encoded>
					
					<wfw:commentRss>https://terragene.com/product/swe-2-7-hygiene-indicator-chemdye-for-use-with-pro-1-endo/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
			</item>
	</channel>
</rss>
