<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>UV Disinfection - Terragene</title>
	<atom:link href="https://terragene.com/product-tag/uv-disinfection/feed/" rel="self" type="application/rss+xml" />
	<link>https://terragene.com</link>
	<description>Biotechnology Company</description>
	<lastBuildDate>Fri, 13 Mar 2026 16:50:18 +0000</lastBuildDate>
	<language>en</language>
	<sy:updatePeriod>
	hourly	</sy:updatePeriod>
	<sy:updateFrequency>
	1	</sy:updateFrequency>
	<generator>https://wordpress.org/?v=6.9.4</generator>

<image>
	<url>https://terragene.com/wp-content/uploads/2020/12/cropped-FAVICON-TERRAGENE-AZUL-Rev.1-32x32.png</url>
	<title>UV Disinfection - Terragene</title>
	<link>https://terragene.com</link>
	<width>32</width>
	<height>32</height>
</image> 
	<item>
		<title>3D Chemical Indicator for UV radiation disinfection</title>
		<link>https://terragene.com/product/3d-chemical-indicator-for-uv-radiation-disinfection/</link>
					<comments>https://terragene.com/product/3d-chemical-indicator-for-uv-radiation-disinfection/#respond</comments>
		
		<dc:creator><![CDATA[Agustin Alvarez]]></dc:creator>
		<pubDate>Thu, 18 Mar 2021 18:20:22 +0000</pubDate>
				<guid isPermaLink="false">https://uvcindicators.com/?post_type=product&#038;p=3153</guid>

					<description><![CDATA[<p>3D Chemical Indicator for disinfection processes control of environments and surfaces by UV light.</p>
<p>Chemdye® ChemSurf CDSUV-1 chemical indicator has been specially developed to control disinfection processes by continuous UV-C radiation. It consists of a pyramidal shape synthetic substrate of 10.5 cm side and 9.0 cm height printed with reactive indicator ink.</p>
<p>The reactive indicator ink has been calibrated to experience different color changes depending on the accumulated radiation dose received, allowing to quickly and accurately control the efficacy of the disinfection process. Chemdye® ChemSurf CDSUV-1 chemical indicator exclusive design allows to dangle it in height and evaluate the accumulated radiation dose received in all directions. See forms of use in height and assemblies.</p>
<p><strong>Instructions for use</strong></p>
<p>1.Mount as many three-dimension Chemdye® ChemSurf CDSUV-1 chemical indicators as areas to be verified, following the specified assembly instructions.</p>
<p>NOTE 1: it is recommended to put special emphasis on shadowed areas, which are those that do not receive radiation directly because something stands between them and the UV source, as they are particularly difficult to disinfect.</p>
<p>2.Leave the room and run a normal disinfection cycle.</p>
<p>3.Once the process has finished, see the final color of each side of each processed Chemdye® ChemSurf CDSUV-1 chemical indicator. If the final color matches the reference color, it means that the accumulated radiation dose received is equal to 200 mJ/cm2.</p>
<p>If the final color is darker (redder) than the reference color, it means that the accumulated radiation dose received is higher than 200 mJ/cm2 . If the final color is lighter (more orange) than the reference color, it means that the accumulated radiation dose received is lower than 200 mJ/cm2.</p>
<p>The attached Documentation Chart allows to quickly register and analyze the obtained results. Chemdye® ChemSurf CDSUV-1 chemical indicator, has also a chart on one of its sides that allows to register its location in the room.</p>
<p>NOTE 2: if Chemdye® ChemSurf CDSUV-1 chemical indicator is placed onto a surface, the side in contact with the surface will not experience any color change due to it will not have been exposed to the disinfectant agent. Chemdye® ChemSurf CDSUV-1 chemical indicator sides may experience different color changes as radiation received on every side might not be the same.</p>
<p>NOTE 3: exposed and non-exposed Chemdye® ChemSurf CDSUV-1 chemical indicators must be kept protected from light. Non-exposed Chemdye® ChemSurf CDSUV-1 chemical indicators must be removed from their original packaging ONLY right before running the disinfection process.</p>
<p>The post <a href="https://terragene.com/product/3d-chemical-indicator-for-uv-radiation-disinfection/">3D Chemical Indicator for UV radiation disinfection</a> first appeared on <a href="https://terragene.com">Terragene</a>.</p>]]></description>
										<content:encoded><![CDATA[<p>3D Chemical Indicator for disinfection processes control of environments and surfaces by UV light.</p>
<p>Chemdye® ChemSurf CDSUV-1 chemical indicator has been specially developed to control disinfection processes by continuous UV-C radiation. It consists of a pyramidal shape synthetic substrate of 10.5 cm side and 9.0 cm height printed with reactive indicator ink.</p>
<p>The reactive indicator ink has been calibrated to experience different color changes depending on the accumulated radiation dose received, allowing to quickly and accurately control the efficacy of the disinfection process. Chemdye® ChemSurf CDSUV-1 chemical indicator exclusive design allows to dangle it in height and evaluate the accumulated radiation dose received in all directions. See forms of use in height and assemblies.</p>
<p><strong>Instructions for use</strong></p>
<p>1.Mount as many three-dimension Chemdye® ChemSurf CDSUV-1 chemical indicators as areas to be verified, following the specified assembly instructions.</p>
<p>NOTE 1: it is recommended to put special emphasis on shadowed areas, which are those that do not receive radiation directly because something stands between them and the UV source, as they are particularly difficult to disinfect.</p>
<p>2.Leave the room and run a normal disinfection cycle.</p>
<p>3.Once the process has finished, see the final color of each side of each processed Chemdye® ChemSurf CDSUV-1 chemical indicator. If the final color matches the reference color, it means that the accumulated radiation dose received is equal to 200 mJ/cm2.</p>
<p>If the final color is darker (redder) than the reference color, it means that the accumulated radiation dose received is higher than 200 mJ/cm2 . If the final color is lighter (more orange) than the reference color, it means that the accumulated radiation dose received is lower than 200 mJ/cm2.</p>
<p>The attached Documentation Chart allows to quickly register and analyze the obtained results. Chemdye® ChemSurf CDSUV-1 chemical indicator, has also a chart on one of its sides that allows to register its location in the room.</p>
<p>NOTE 2: if Chemdye® ChemSurf CDSUV-1 chemical indicator is placed onto a surface, the side in contact with the surface will not experience any color change due to it will not have been exposed to the disinfectant agent. Chemdye® ChemSurf CDSUV-1 chemical indicator sides may experience different color changes as radiation received on every side might not be the same.</p>
<p>NOTE 3: exposed and non-exposed Chemdye® ChemSurf CDSUV-1 chemical indicators must be kept protected from light. Non-exposed Chemdye® ChemSurf CDSUV-1 chemical indicators must be removed from their original packaging ONLY right before running the disinfection process.</p>
<p>The post <a href="https://terragene.com/product/3d-chemical-indicator-for-uv-radiation-disinfection/">3D Chemical Indicator for UV radiation disinfection</a> first appeared on <a href="https://terragene.com">Terragene</a>.</p>]]></content:encoded>
					
					<wfw:commentRss>https://terragene.com/product/3d-chemical-indicator-for-uv-radiation-disinfection/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
			</item>
		<item>
		<title>UV dosimeter for UV-C radiation disinfection &#8211; 100</title>
		<link>https://terragene.com/product/uv-dosimeter-for-uv-c-radiation-disinfection-100/</link>
					<comments>https://terragene.com/product/uv-dosimeter-for-uv-c-radiation-disinfection-100/#respond</comments>
		
		<dc:creator><![CDATA[Agustin Alvarez]]></dc:creator>
		<pubDate>Thu, 18 Mar 2021 18:20:18 +0000</pubDate>
				<guid isPermaLink="false">https://uvcindicators.com/products/uv-dosimeter-for-uv-c-radiation-disinfection-100/</guid>

					<description><![CDATA[<p>Self-adhesive labels printed with reactive ink to control disinfection processes by UV-C radiation up to 25 mj/cm2. DOSIMETER.</p>
<p><strong>Instructions for use</strong></p>
<p>1. Peel off Chemdye® ChemDose CD87-100 chemical indicator from the roll and stick it on the surface which level of disinfection is pretended to be controlled. Use as many indicators as surfaces intended to be verified.</p>
<p>NOTE 1: it is recommended to distribute Chemdye® ChemDose CD87-100 chemical indicators uniformly along the room to be disinfected, placing at least one per square meter. It is recommended to place Chemdye® ChemDose CD87-100 chemical indicators not higher than 2 m over the floor level.</p>
<p>2. Leave the room and run a normal disinfection cycle.</p>
<p>3. Once the process has finished, contrast the final color of each Chemdye® ChemDose CD87-100 chemical indicator used against the Results Reference Card provided and determine the accumulated radiation dose received. The attached Documentation Chart allows to quickly record and analyze the obtained results.</p>
<p>NOTE 2: exposed and non-exposed Chemdye® ChemDose CD87-100 chemical indicators must be kept protected from light. Non-exposed Chemdye® ChemDose CD87-100 chemical indicators must be removed from its original packaging ONLY right before running the disinfection process.</p>
<p><strong>Instructions for use</strong></p>
<p>1. Peel off Chemdye® ChemDose CD87-100 chemical indicator from the roll and stick it on the surface which level of disinfection is pretended to be controlled. Use as many indicators as surfaces intended to be verified.</p>
<p>NOTE 1: it is recommended to distribute Chemdye® ChemDose CD87-100 chemical indicators uniformly along the room to be disinfected, placing at least one per square meter. It is recommended to place Chemdye® ChemDose CD87-100 chemical indicators not higher than 2 m over the floor level.</p>
<p>2. Leave the room and run a normal disinfection cycle.</p>
<p>3. Once the process has finished, contrast the final color of each Chemdye® ChemDose CD87-100 chemical indicator used against the Results Reference Card provided and determine the accumulated radiation dose received. The attached Documentation Chart allows to quickly record and analyze the obtained results.</p>
<p>NOTE 2: exposed and non-exposed Chemdye® ChemDose CD87-100 chemical indicators must be kept protected from light. Non-exposed Chemdye® ChemDose CD87-100 chemical indicators must be removed from its original packaging ONLY right before running the disinfection process.</p>
<p>The post <a href="https://terragene.com/product/uv-dosimeter-for-uv-c-radiation-disinfection-100/">UV dosimeter for UV-C radiation disinfection – 100</a> first appeared on <a href="https://terragene.com">Terragene</a>.</p>]]></description>
										<content:encoded><![CDATA[<p>Self-adhesive labels printed with reactive ink to control disinfection processes by UV-C radiation up to 25 mj/cm2. DOSIMETER.</p>
<p><strong>Instructions for use</strong></p>
<p>1. Peel off Chemdye® ChemDose CD87-100 chemical indicator from the roll and stick it on the surface which level of disinfection is pretended to be controlled. Use as many indicators as surfaces intended to be verified.</p>
<p>NOTE 1: it is recommended to distribute Chemdye® ChemDose CD87-100 chemical indicators uniformly along the room to be disinfected, placing at least one per square meter. It is recommended to place Chemdye® ChemDose CD87-100 chemical indicators not higher than 2 m over the floor level.</p>
<p>2. Leave the room and run a normal disinfection cycle.</p>
<p>3. Once the process has finished, contrast the final color of each Chemdye® ChemDose CD87-100 chemical indicator used against the Results Reference Card provided and determine the accumulated radiation dose received. The attached Documentation Chart allows to quickly record and analyze the obtained results.</p>
<p>NOTE 2: exposed and non-exposed Chemdye® ChemDose CD87-100 chemical indicators must be kept protected from light. Non-exposed Chemdye® ChemDose CD87-100 chemical indicators must be removed from its original packaging ONLY right before running the disinfection process.</p>
<p><strong>Instructions for use</strong></p>
<p>1. Peel off Chemdye® ChemDose CD87-100 chemical indicator from the roll and stick it on the surface which level of disinfection is pretended to be controlled. Use as many indicators as surfaces intended to be verified.</p>
<p>NOTE 1: it is recommended to distribute Chemdye® ChemDose CD87-100 chemical indicators uniformly along the room to be disinfected, placing at least one per square meter. It is recommended to place Chemdye® ChemDose CD87-100 chemical indicators not higher than 2 m over the floor level.</p>
<p>2. Leave the room and run a normal disinfection cycle.</p>
<p>3. Once the process has finished, contrast the final color of each Chemdye® ChemDose CD87-100 chemical indicator used against the Results Reference Card provided and determine the accumulated radiation dose received. The attached Documentation Chart allows to quickly record and analyze the obtained results.</p>
<p>NOTE 2: exposed and non-exposed Chemdye® ChemDose CD87-100 chemical indicators must be kept protected from light. Non-exposed Chemdye® ChemDose CD87-100 chemical indicators must be removed from its original packaging ONLY right before running the disinfection process.</p>
<p>The post <a href="https://terragene.com/product/uv-dosimeter-for-uv-c-radiation-disinfection-100/">UV dosimeter for UV-C radiation disinfection – 100</a> first appeared on <a href="https://terragene.com">Terragene</a>.</p>]]></content:encoded>
					
					<wfw:commentRss>https://terragene.com/product/uv-dosimeter-for-uv-c-radiation-disinfection-100/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
			</item>
		<item>
		<title>UV dosimeter for UV-C radiation disinfection &#8211; 200G</title>
		<link>https://terragene.com/product/uv-dosimeter-for-uv-c-radiation-disinfection-200g/</link>
					<comments>https://terragene.com/product/uv-dosimeter-for-uv-c-radiation-disinfection-200g/#respond</comments>
		
		<dc:creator><![CDATA[Agustin Alvarez]]></dc:creator>
		<pubDate>Tue, 23 Feb 2021 11:32:12 +0000</pubDate>
				<guid isPermaLink="false">https://terragene.com/?post_type=product&#038;p=30044</guid>

					<description><![CDATA[<p>It has been demonstrated that many microorganisms can be inactivated by continuous UV-C radiation. UV-C radiation is absorbed by DNA and RNA, causing changes in their structures and preventing their replication. The radiation dose required to achieve a microbial load reduction depends not only on the particular microorganism, but also on additional factors like radiation intensity (power) of the emitting source, distance between emitting source and surface, and time of exposure. Furthermore, surfaces that only receive radiation by reflection, get lower doses that may not be sufficient to incativate the pathogenic microorganisms present. Considering all this, it is of utmost importance to control that all surfaces to be disinfected, receive the minimum radiation dose required.</p>
<p>Product description</p>
<p>Chemdye® ChemDose CD87-200G chemical indicator has been specially developed to control disinfection processes by continuous UV-C radiation. It consists of a 15 mm diameter dot of self-adhesive synthetic substrateprinted with reactive indicating ink. The reactive indicating ink has been calibrated to experience different color changes depending on the accumulated radiation dose received, allowing to quickly and accurately control the efficacy of the disinfection process.</p>
<p>Instructions for use</p>
<ol>
<li>Peel off Chemdye® ChemDose CD87-200G chemical indicator from the roll and stick it on the surface which level of disinfection is pretended to be cpontrolled. Use as many indicators as surfaces inteded to be verified.</li>
</ol>
<p>NOTE 1: It is recommended to distribute Chemdye® ChemDose CD87-200G chemical indicators uniformly along the room to be disinfected, placing at least one per square meter. It is recommended to place Chemdye® ChemDose CD87-200G chemical indicators not higher than 2 m over the floor level.</p>
<ol start="2">
<li>Leave the room and run a normal disinfection cycle.</li>
<li>Once the process has finished, contrast the final color of each.</li>
</ol>
<p>Chemdye® ChemDose CD87-200G chemical indicator used against the Results Reference Card provided and determine the accumulated radiation dose received. Confirm the color change with the results Reference Card immediately or within 24 hours for best results.</p>
<p>NOTE 2: Exposed and non-exposed Chemdye® ChemDose CD87-200G chemical indicators must be kept protected from light. Non-exposed Chemdye® ChemDose CD87-200G chemical indicators must be removed from its original packaging ONLY right before running the disinfection process.</p>
<p>NOTE 3: record the result immediately after the disinfection process.</p>
<p>NOTE 4: if any serious incident occurs in relation to the device, it should be</p>
<p>reported to Terragene S.A. and the competent authority of the State in which</p>
<p>the user is established.</p>
<p>The post <a href="https://terragene.com/product/uv-dosimeter-for-uv-c-radiation-disinfection-200g/">UV dosimeter for UV-C radiation disinfection – 200G</a> first appeared on <a href="https://terragene.com">Terragene</a>.</p>]]></description>
										<content:encoded><![CDATA[<p>It has been demonstrated that many microorganisms can be inactivated by continuous UV-C radiation. UV-C radiation is absorbed by DNA and RNA, causing changes in their structures and preventing their replication. The radiation dose required to achieve a microbial load reduction depends not only on the particular microorganism, but also on additional factors like radiation intensity (power) of the emitting source, distance between emitting source and surface, and time of exposure. Furthermore, surfaces that only receive radiation by reflection, get lower doses that may not be sufficient to incativate the pathogenic microorganisms present. Considering all this, it is of utmost importance to control that all surfaces to be disinfected, receive the minimum radiation dose required.</p>
<p>Product description</p>
<p>Chemdye® ChemDose CD87-200G chemical indicator has been specially developed to control disinfection processes by continuous UV-C radiation. It consists of a 15 mm diameter dot of self-adhesive synthetic substrateprinted with reactive indicating ink. The reactive indicating ink has been calibrated to experience different color changes depending on the accumulated radiation dose received, allowing to quickly and accurately control the efficacy of the disinfection process.</p>
<p>Instructions for use</p>
<ol>
<li>Peel off Chemdye® ChemDose CD87-200G chemical indicator from the roll and stick it on the surface which level of disinfection is pretended to be cpontrolled. Use as many indicators as surfaces inteded to be verified.</li>
</ol>
<p>NOTE 1: It is recommended to distribute Chemdye® ChemDose CD87-200G chemical indicators uniformly along the room to be disinfected, placing at least one per square meter. It is recommended to place Chemdye® ChemDose CD87-200G chemical indicators not higher than 2 m over the floor level.</p>
<ol start="2">
<li>Leave the room and run a normal disinfection cycle.</li>
<li>Once the process has finished, contrast the final color of each.</li>
</ol>
<p>Chemdye® ChemDose CD87-200G chemical indicator used against the Results Reference Card provided and determine the accumulated radiation dose received. Confirm the color change with the results Reference Card immediately or within 24 hours for best results.</p>
<p>NOTE 2: Exposed and non-exposed Chemdye® ChemDose CD87-200G chemical indicators must be kept protected from light. Non-exposed Chemdye® ChemDose CD87-200G chemical indicators must be removed from its original packaging ONLY right before running the disinfection process.</p>
<p>NOTE 3: record the result immediately after the disinfection process.</p>
<p>NOTE 4: if any serious incident occurs in relation to the device, it should be</p>
<p>reported to Terragene S.A. and the competent authority of the State in which</p>
<p>the user is established.</p>
<p>The post <a href="https://terragene.com/product/uv-dosimeter-for-uv-c-radiation-disinfection-200g/">UV dosimeter for UV-C radiation disinfection – 200G</a> first appeared on <a href="https://terragene.com">Terragene</a>.</p>]]></content:encoded>
					
					<wfw:commentRss>https://terragene.com/product/uv-dosimeter-for-uv-c-radiation-disinfection-200g/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		