<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>Cleaning indicators - Terragene</title>
	<atom:link href="https://terragene.com/product-tag/cleaning-indicators/feed/" rel="self" type="application/rss+xml" />
	<link>https://terragene.com</link>
	<description>Biotechnology Company</description>
	<lastBuildDate>Tue, 20 Jan 2026 16:45:54 +0000</lastBuildDate>
	<language>en</language>
	<sy:updatePeriod>
	hourly	</sy:updatePeriod>
	<sy:updateFrequency>
	1	</sy:updateFrequency>
	<generator>https://wordpress.org/?v=6.9.4</generator>

<image>
	<url>https://terragene.com/wp-content/uploads/2020/12/cropped-FAVICON-TERRAGENE-AZUL-Rev.1-32x32.png</url>
	<title>Cleaning indicators - Terragene</title>
	<link>https://terragene.com</link>
	<width>32</width>
	<height>32</height>
</image> 
	<item>
		<title>High absorption swabs Chemdye® for use with PRO1 ENDO</title>
		<link>https://terragene.com/product/swe-3-hygiene-indicator-chemdye-for-use-with-pro-1-endo/</link>
					<comments>https://terragene.com/product/swe-3-hygiene-indicator-chemdye-for-use-with-pro-1-endo/#respond</comments>
		
		<dc:creator><![CDATA[infraestructura]]></dc:creator>
		<pubDate>Fri, 14 Mar 2025 20:00:27 +0000</pubDate>
				<guid isPermaLink="false">https://terragene.com/?post_type=product&#038;p=48419</guid>

					<description><![CDATA[<p><b>Usage</b><br />
Chemdye® SWE high-absorption swabs have been specifically designed for use with cannulated instruments. These swabs must be inserted through the internal channel of the cannula, allowing the collection of contaminants that may persist after the cleaning process. SWE swabs are designed for use with Chemdye® PRO 1 ENDO system, enabling the verification of the cleaning efficacy of cannulated instruments by detecting and quantifying protein residues that may remain after the cleaning process.</p>
<p><b>Characteristics</b><br />
Length: 2.5 m.<br />
Diameter: 3.0 mm.<br />
Recommended swab diameter:</p>
<p><img class="alignnone size-medium wp-image-48416" src="https://terragene.com/wp-content/uploads/dimentions_details_grid-300x85.png" alt="dimentions_details" width="300" height="85" /></p>
<p><b>Storage conditions</b><br />
Chemdye® SWE swabs should be stored at temperatures between 15-30 °C, protected from light and relative humidity (RH) of 20-80 %.</p>
<p><b>Transport conditions</b><br />
It is recommended to respect storage conditions during transport. Transport in closed and strengthened boxes in order to avoid damages. The transport of this product does not represent a risk for health.</p>
<p><b>Shelf life</b><br />
24 months when stored at the declared temperatures.</p>
<p><b>Packaging</b><br />
Box with 5 units.<br />
Packaging information: product code and description, presentation, storage conditions, manufacturer information and data on label.</p>
<p><b>Labelling</b><br />
On product’s box: product code, batch number, manufacture and expiration date, bar code and datamatrix code.<br />
<b>Possible target markets</b><br />
Healthcare, Pharmaceutical and Medical industries.</p>
<p><b>Other important information</b><br />
Read product’s instructions for use thoroughly before use.</p>
<p><b>Precautions</b><br />
Handle with gloves at all times.<br />
Do not open until use.<br />
Do not reuse.<br />
Do not re-incubate.<br />
Do not swab surfaces that have not been subjected to a cleaning process or visibly contaminated areas. Avoid touching the absorbent part of the swab or the inside of the device with your hands. Use gloves, a mask and other hygiene measures.<br />
Do not freeze.<br />
Do not use Chemdye® SWE swabs on any device other than</p>
<p>Chemdye® PRO 1 ENDO.<br />
High concentrations of alkaline detergents may cause false-negative results in some cases. Oxidizing disinfectants (such as hydrogen peroxide or peracetic acid) may cause a false-positive color change reaction. Although Chemdye® PRO 1 ENDO has high sensitivity, its intended use corresponds to the monitoring of channels after the cleaning process, so the test result is not evidence that the device is sterile.</p>
<p>The post <a href="https://terragene.com/product/swe-3-hygiene-indicator-chemdye-for-use-with-pro-1-endo/">High absorption swabs Chemdye® for use with PRO1 ENDO</a> first appeared on <a href="https://terragene.com">Terragene</a>.</p>]]></description>
										<content:encoded><![CDATA[<p><b>Usage</b><br />
Chemdye® SWE high-absorption swabs have been specifically designed for use with cannulated instruments. These swabs must be inserted through the internal channel of the cannula, allowing the collection of contaminants that may persist after the cleaning process. SWE swabs are designed for use with Chemdye® PRO 1 ENDO system, enabling the verification of the cleaning efficacy of cannulated instruments by detecting and quantifying protein residues that may remain after the cleaning process.</p>
<p><b>Characteristics</b><br />
Length: 2.5 m.<br />
Diameter: 3.0 mm.<br />
Recommended swab diameter:</p>
<p><img class="alignnone size-medium wp-image-48416" src="https://terragene.com/wp-content/uploads/dimentions_details_grid-300x85.png" alt="dimentions_details" width="300" height="85" /></p>
<p><b>Storage conditions</b><br />
Chemdye® SWE swabs should be stored at temperatures between 15-30 °C, protected from light and relative humidity (RH) of 20-80 %.</p>
<p><b>Transport conditions</b><br />
It is recommended to respect storage conditions during transport. Transport in closed and strengthened boxes in order to avoid damages. The transport of this product does not represent a risk for health.</p>
<p><b>Shelf life</b><br />
24 months when stored at the declared temperatures.</p>
<p><b>Packaging</b><br />
Box with 5 units.<br />
Packaging information: product code and description, presentation, storage conditions, manufacturer information and data on label.</p>
<p><b>Labelling</b><br />
On product’s box: product code, batch number, manufacture and expiration date, bar code and datamatrix code.<br />
<b>Possible target markets</b><br />
Healthcare, Pharmaceutical and Medical industries.</p>
<p><b>Other important information</b><br />
Read product’s instructions for use thoroughly before use.</p>
<p><b>Precautions</b><br />
Handle with gloves at all times.<br />
Do not open until use.<br />
Do not reuse.<br />
Do not re-incubate.<br />
Do not swab surfaces that have not been subjected to a cleaning process or visibly contaminated areas. Avoid touching the absorbent part of the swab or the inside of the device with your hands. Use gloves, a mask and other hygiene measures.<br />
Do not freeze.<br />
Do not use Chemdye® SWE swabs on any device other than</p>
<p>Chemdye® PRO 1 ENDO.<br />
High concentrations of alkaline detergents may cause false-negative results in some cases. Oxidizing disinfectants (such as hydrogen peroxide or peracetic acid) may cause a false-positive color change reaction. Although Chemdye® PRO 1 ENDO has high sensitivity, its intended use corresponds to the monitoring of channels after the cleaning process, so the test result is not evidence that the device is sterile.</p>
<p>The post <a href="https://terragene.com/product/swe-3-hygiene-indicator-chemdye-for-use-with-pro-1-endo/">High absorption swabs Chemdye® for use with PRO1 ENDO</a> first appeared on <a href="https://terragene.com">Terragene</a>.</p>]]></content:encoded>
					
					<wfw:commentRss>https://terragene.com/product/swe-3-hygiene-indicator-chemdye-for-use-with-pro-1-endo/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
			</item>
		<item>
		<title>High absorption swabs Chemdye® for use with PRO1 ENDO</title>
		<link>https://terragene.com/product/swe-2-7-hygiene-indicator-chemdye-for-use-with-pro-1-endo/</link>
					<comments>https://terragene.com/product/swe-2-7-hygiene-indicator-chemdye-for-use-with-pro-1-endo/#respond</comments>
		
		<dc:creator><![CDATA[infraestructura]]></dc:creator>
		<pubDate>Fri, 14 Mar 2025 19:33:08 +0000</pubDate>
				<guid isPermaLink="false">https://terragene.com/?post_type=product&#038;p=48410</guid>

					<description><![CDATA[<p><b>Usage</b><br />
Chemdye® SWE high-absorption swabs have been specifically designed for use with cannulated instruments. These swabs must be inserted through the internal channel of the cannula, allowing the collection of contaminants that may persist after the cleaning process. SWE swabs are designed for use with Chemdye® PRO 1 ENDO system, enabling the verification of the cleaning efficacy of cannulated instruments by detecting and quantifying protein residues that may remain after the cleaning process.</p>
<p><b>Characteristics</b><br />
Length: 2.5 m.<br />
Diameter: 2.7 mm.<br />
Recommended swab diameter:</p>
<p><img class="alignnone size-medium wp-image-48416" src="https://terragene.com/wp-content/uploads/dimentions_details_grid-300x85.png" alt="dimentions_details" width="300" height="85" /></p>
<p><b>Storage conditions</b><br />
Chemdye® SWE swabs should be stored at temperatures between 15-30 °C, protected from light and relative humidity (RH) of 20-80 %.</p>
<p><b>Transport conditions</b><br />
It is recommended to respect storage conditions during transport. Transport in closed and strengthened boxes in order to avoid damages. The transport of this product does not represent a risk for health.</p>
<p><b>Shelf life</b><br />
24 months when stored at the declared temperatures.</p>
<p><b>Packaging</b><br />
Box with 5 units.<br />
Packaging information: product code and description, presentation, storage conditions, manufacturer information and data on label.</p>
<p><b>Labelling</b><br />
On product’s box: product code, batch number, manufacture and expiration date, bar code and datamatrix code.</p>
<p><b>Possible target markets</b><br />
Healthcare, Pharmaceutical and Medical industries.</p>
<p><b>Other important information</b><br />
Read product’s instructions for use thoroughly before use.</p>
<p><b>Precautions</b><br />
Handle with gloves at all times.<br />
Do not open until use.<br />
Do not reuse.<br />
Do not re-incubate.<br />
Do not swab surfaces that have not been subjected to a cleaning<br />
process or visibly contaminated areas.<br />
Avoid touching the absorbent part of the swab or the inside of the<br />
device with your hands.<br />
Use gloves, a mask and other hygiene measures.<br />
Do not freeze.<br />
Do not use Chemdye® SWE swabs on any device other than</p>
<p>Chemdye® PRO 1 ENDO.<br />
High concentrations of alkaline detergents may cause false-negative results in some cases. Oxidizing disinfectants (such as hydrogen peroxide or peracetic acid) may cause a false-positive color change reaction. Although Chemdye® PRO1 ENDO has high sensitivity, its intended use corresponds to the monitoring of channels after the cleaning process, so the test result is not evidence that the device is sterile.</p>
<p>The post <a href="https://terragene.com/product/swe-2-7-hygiene-indicator-chemdye-for-use-with-pro-1-endo/">High absorption swabs Chemdye® for use with PRO1 ENDO</a> first appeared on <a href="https://terragene.com">Terragene</a>.</p>]]></description>
										<content:encoded><![CDATA[<p><b>Usage</b><br />
Chemdye® SWE high-absorption swabs have been specifically designed for use with cannulated instruments. These swabs must be inserted through the internal channel of the cannula, allowing the collection of contaminants that may persist after the cleaning process. SWE swabs are designed for use with Chemdye® PRO 1 ENDO system, enabling the verification of the cleaning efficacy of cannulated instruments by detecting and quantifying protein residues that may remain after the cleaning process.</p>
<p><b>Characteristics</b><br />
Length: 2.5 m.<br />
Diameter: 2.7 mm.<br />
Recommended swab diameter:</p>
<p><img class="alignnone size-medium wp-image-48416" src="https://terragene.com/wp-content/uploads/dimentions_details_grid-300x85.png" alt="dimentions_details" width="300" height="85" /></p>
<p><b>Storage conditions</b><br />
Chemdye® SWE swabs should be stored at temperatures between 15-30 °C, protected from light and relative humidity (RH) of 20-80 %.</p>
<p><b>Transport conditions</b><br />
It is recommended to respect storage conditions during transport. Transport in closed and strengthened boxes in order to avoid damages. The transport of this product does not represent a risk for health.</p>
<p><b>Shelf life</b><br />
24 months when stored at the declared temperatures.</p>
<p><b>Packaging</b><br />
Box with 5 units.<br />
Packaging information: product code and description, presentation, storage conditions, manufacturer information and data on label.</p>
<p><b>Labelling</b><br />
On product’s box: product code, batch number, manufacture and expiration date, bar code and datamatrix code.</p>
<p><b>Possible target markets</b><br />
Healthcare, Pharmaceutical and Medical industries.</p>
<p><b>Other important information</b><br />
Read product’s instructions for use thoroughly before use.</p>
<p><b>Precautions</b><br />
Handle with gloves at all times.<br />
Do not open until use.<br />
Do not reuse.<br />
Do not re-incubate.<br />
Do not swab surfaces that have not been subjected to a cleaning<br />
process or visibly contaminated areas.<br />
Avoid touching the absorbent part of the swab or the inside of the<br />
device with your hands.<br />
Use gloves, a mask and other hygiene measures.<br />
Do not freeze.<br />
Do not use Chemdye® SWE swabs on any device other than</p>
<p>Chemdye® PRO 1 ENDO.<br />
High concentrations of alkaline detergents may cause false-negative results in some cases. Oxidizing disinfectants (such as hydrogen peroxide or peracetic acid) may cause a false-positive color change reaction. Although Chemdye® PRO1 ENDO has high sensitivity, its intended use corresponds to the monitoring of channels after the cleaning process, so the test result is not evidence that the device is sterile.</p>
<p>The post <a href="https://terragene.com/product/swe-2-7-hygiene-indicator-chemdye-for-use-with-pro-1-endo/">High absorption swabs Chemdye® for use with PRO1 ENDO</a> first appeared on <a href="https://terragene.com">Terragene</a>.</p>]]></content:encoded>
					
					<wfw:commentRss>https://terragene.com/product/swe-2-7-hygiene-indicator-chemdye-for-use-with-pro-1-endo/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
			</item>
		<item>
		<title>High absorption swabs Chemdye® for use with PRO1 ENDO</title>
		<link>https://terragene.com/product/swe-2-0-hygiene-indicator-chemdye-for-use-with-pro-1-endo/</link>
					<comments>https://terragene.com/product/swe-2-0-hygiene-indicator-chemdye-for-use-with-pro-1-endo/#respond</comments>
		
		<dc:creator><![CDATA[infraestructura]]></dc:creator>
		<pubDate>Fri, 14 Mar 2025 18:42:23 +0000</pubDate>
				<guid isPermaLink="false">https://terragene.com/?post_type=product&#038;p=48405</guid>

					<description><![CDATA[<p><b>Usage</b><br />
Chemdye® SWE high-absorption swabs have been specifically designed for use with cannulated instruments. These swabs must be inserted through the internal channel of the cannula, allowing the collection of contaminants that may persist after the cleaning process. SWE swabs are designed for use with Chemdye® PRO 1 ENDO system, enabling the verification of the cleaning efficacy of cannulated instruments by detecting and quantifying protein residues that may remain after the cleaning process.</p>
<p><b>Characteristics</b><br />
Length: 2.5 m.<br />
Diameter: 2.0 mm.<br />
Recommended swab diameter:<br />
<img class="alignnone size-medium wp-image-48416" src="https://terragene.com/wp-content/uploads/dimentions_details_grid-300x85.png" alt="dimentions_details" width="300" height="85" /></p>
<p><b>Storage conditions</b><br />
Chemdye® SWE swabs should be stored at temperatures between 15-30 °C, protected from light and relative humidity (RH) of 20-80 %.</p>
<p><b>Transport conditions</b><br />
It is recommended to respect storage conditions during transport. Transport in closed and strengthened boxes in order to avoid damages. The transport of this product does not represent a risk for health.</p>
<p><b>Shelf life</b><br />
24 months when stored at the declared temperatures.</p>
<p><b>Packaging</b><br />
Box with 5 units.<br />
Packaging information: product code and description, presentation, storage conditions, manufacturer information and data on label.</p>
<p><b>Labelling</b><br />
On product’s box: product code, batch number, manufacture and expiration date, bar code and datamatrix code.</p>
<p><b>Possible target markets</b><br />
Healthcare, Pharmaceutical and Medical industries.</p>
<p><b>Other important information</b><br />
Read product’s instructions for use thoroughly before use.</p>
<p><b>Precautions</b><br />
Handle with gloves at all times.<br />
Do not open until use.<br />
Do not reuse.<br />
Do not re-incubate.<br />
Do not swab surfaces that have not been subjected to a cleaning process or visibly contaminated areas. Avoid touching the absorbent part of the swab or the inside of the device with your hands. Use gloves, a mask and other hygiene measures.<br />
Do not freeze.<br />
Do not use Chemdye® SWE swabs on any device other than</p>
<p>Chemdye® PRO 1 ENDO.<br />
High concentrations of alkaline detergents may cause false-negative results in some cases. Oxidizing disinfectants (such as hydrogen peroxide or peracetic acid) may cause a false-positive color change reaction. Although Chemdye® PRO1 ENDO has high sensitivity, its intended use corresponds to the monitoring of channels after the cleaning process, so the test result is not evidence that the device is sterile</p>
<p>The post <a href="https://terragene.com/product/swe-2-0-hygiene-indicator-chemdye-for-use-with-pro-1-endo/">High absorption swabs Chemdye® for use with PRO1 ENDO</a> first appeared on <a href="https://terragene.com">Terragene</a>.</p>]]></description>
										<content:encoded><![CDATA[<p><b>Usage</b><br />
Chemdye® SWE high-absorption swabs have been specifically designed for use with cannulated instruments. These swabs must be inserted through the internal channel of the cannula, allowing the collection of contaminants that may persist after the cleaning process. SWE swabs are designed for use with Chemdye® PRO 1 ENDO system, enabling the verification of the cleaning efficacy of cannulated instruments by detecting and quantifying protein residues that may remain after the cleaning process.</p>
<p><b>Characteristics</b><br />
Length: 2.5 m.<br />
Diameter: 2.0 mm.<br />
Recommended swab diameter:<br />
<img class="alignnone size-medium wp-image-48416" src="https://terragene.com/wp-content/uploads/dimentions_details_grid-300x85.png" alt="dimentions_details" width="300" height="85" /></p>
<p><b>Storage conditions</b><br />
Chemdye® SWE swabs should be stored at temperatures between 15-30 °C, protected from light and relative humidity (RH) of 20-80 %.</p>
<p><b>Transport conditions</b><br />
It is recommended to respect storage conditions during transport. Transport in closed and strengthened boxes in order to avoid damages. The transport of this product does not represent a risk for health.</p>
<p><b>Shelf life</b><br />
24 months when stored at the declared temperatures.</p>
<p><b>Packaging</b><br />
Box with 5 units.<br />
Packaging information: product code and description, presentation, storage conditions, manufacturer information and data on label.</p>
<p><b>Labelling</b><br />
On product’s box: product code, batch number, manufacture and expiration date, bar code and datamatrix code.</p>
<p><b>Possible target markets</b><br />
Healthcare, Pharmaceutical and Medical industries.</p>
<p><b>Other important information</b><br />
Read product’s instructions for use thoroughly before use.</p>
<p><b>Precautions</b><br />
Handle with gloves at all times.<br />
Do not open until use.<br />
Do not reuse.<br />
Do not re-incubate.<br />
Do not swab surfaces that have not been subjected to a cleaning process or visibly contaminated areas. Avoid touching the absorbent part of the swab or the inside of the device with your hands. Use gloves, a mask and other hygiene measures.<br />
Do not freeze.<br />
Do not use Chemdye® SWE swabs on any device other than</p>
<p>Chemdye® PRO 1 ENDO.<br />
High concentrations of alkaline detergents may cause false-negative results in some cases. Oxidizing disinfectants (such as hydrogen peroxide or peracetic acid) may cause a false-positive color change reaction. Although Chemdye® PRO1 ENDO has high sensitivity, its intended use corresponds to the monitoring of channels after the cleaning process, so the test result is not evidence that the device is sterile</p>
<p>The post <a href="https://terragene.com/product/swe-2-0-hygiene-indicator-chemdye-for-use-with-pro-1-endo/">High absorption swabs Chemdye® for use with PRO1 ENDO</a> first appeared on <a href="https://terragene.com">Terragene</a>.</p>]]></content:encoded>
					
					<wfw:commentRss>https://terragene.com/product/swe-2-0-hygiene-indicator-chemdye-for-use-with-pro-1-endo/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
			</item>
		<item>
		<title>High absorption swabs Chemdye® for use with PRO1 ENDO</title>
		<link>https://terragene.com/product/swe-1-7-hygiene-indicator-chemdye-for-use-with-pro1-endo/</link>
					<comments>https://terragene.com/product/swe-1-7-hygiene-indicator-chemdye-for-use-with-pro1-endo/#respond</comments>
		
		<dc:creator><![CDATA[infraestructura]]></dc:creator>
		<pubDate>Fri, 14 Mar 2025 17:54:57 +0000</pubDate>
				<guid isPermaLink="false">https://terragene.com/?post_type=product&#038;p=48395</guid>

					<description><![CDATA[<p>Chemdye® SWE high-absorption swabs for use with Chemdye® PRO1 ENDO</p>
<p><b>Usage:</b><br />
Chemdye® SWE high-absorption swabs have been specifically designed for use with cannulated instruments. These swabs must be inserted through the internal channel of the cannula, allowing the collection of contaminants that may persist after the cleaning process. SWE swabs are designed for use with Chemdye® PRO1 ENDO system, enabling the verification of the cleaning efficacy of cannulated instruments by detecting and quantifying protein residues that may remain after the cleaning process.</p>
<p><b>Characteristics:</b><br />
Length: 2.5 m.<br />
Diameter: 1.7 mm.<br />
Recommended swab diameter:</p>
<p><img class="alignnone size-medium wp-image-48416" src="https://terragene.com/wp-content/uploads/dimentions_details_grid-300x85.png" alt="dimentions_details" width="300" height="85" /></p>
<p><b>Storage conditions</b><br />
Chemdye® SWE swabs should be stored at temperatures between 15-30 °C, protected from light and relative humidity (RH) of 20-80 %.</p>
<p><b>Transport conditions</b><br />
It is recommended to respect storage conditions during transport. Transport in closed and strengthened boxes in order to avoid damages. The transport of this product does not represent a risk for health.</p>
<p><b>Shelf life</b><br />
24 months when stored at the declared temperatures.</p>
<p><b>Packaging</b><br />
Box with 5 units.</p>
<p><b>Packaging information:</b><br />
Product code and description, presentation, storage conditions, manufacturer information and data on label.</p>
<p><b>Labelling</b><br />
On product’s box: product code, batch number, manufacture and expiration date, bar code and datamatrix code.</p>
<p><b>Possible target markets:</b><br />
Healthcare, Pharmaceutical and Medical industries.</p>
<p><b>Other important information.</b><br />
Read product’s instructions for use thoroughly before use.</p>
<p><b>Precautions</b><br />
Handle with gloves at all times.<br />
Do not open until use.<br />
Do not reuse.<br />
Do not re-incubate.<br />
Do not swab surfaces that have not been subjected to a cleaning process or visibly contaminated areas.<br />
Avoid touching the absorbent part of the swab or the inside of the device with your hands. Use gloves, a mask and other hygiene measures.<br />
Do not freeze.<br />
Do not use Chemdye® SWE swabs on any device other than</p>
<p>Chemdye® PRO 1 ENDO.<br />
High concentrations of alkaline detergents may cause false-negative results in some cases. Oxidizing disinfectants (such as hydrogen peroxide or peracetic acid) may cause a false-positive color change reaction. Although Chemdye® PRO1 ENDO has high sensitivity, its intended use corresponds to the monitoring of channels after the cleaning process, so the test result is not evidence that the device is sterile.</p>
<p>The post <a href="https://terragene.com/product/swe-1-7-hygiene-indicator-chemdye-for-use-with-pro1-endo/">High absorption swabs Chemdye® for use with PRO1 ENDO</a> first appeared on <a href="https://terragene.com">Terragene</a>.</p>]]></description>
										<content:encoded><![CDATA[<p>Chemdye® SWE high-absorption swabs for use with Chemdye® PRO1 ENDO</p>
<p><b>Usage:</b><br />
Chemdye® SWE high-absorption swabs have been specifically designed for use with cannulated instruments. These swabs must be inserted through the internal channel of the cannula, allowing the collection of contaminants that may persist after the cleaning process. SWE swabs are designed for use with Chemdye® PRO1 ENDO system, enabling the verification of the cleaning efficacy of cannulated instruments by detecting and quantifying protein residues that may remain after the cleaning process.</p>
<p><b>Characteristics:</b><br />
Length: 2.5 m.<br />
Diameter: 1.7 mm.<br />
Recommended swab diameter:</p>
<p><img class="alignnone size-medium wp-image-48416" src="https://terragene.com/wp-content/uploads/dimentions_details_grid-300x85.png" alt="dimentions_details" width="300" height="85" /></p>
<p><b>Storage conditions</b><br />
Chemdye® SWE swabs should be stored at temperatures between 15-30 °C, protected from light and relative humidity (RH) of 20-80 %.</p>
<p><b>Transport conditions</b><br />
It is recommended to respect storage conditions during transport. Transport in closed and strengthened boxes in order to avoid damages. The transport of this product does not represent a risk for health.</p>
<p><b>Shelf life</b><br />
24 months when stored at the declared temperatures.</p>
<p><b>Packaging</b><br />
Box with 5 units.</p>
<p><b>Packaging information:</b><br />
Product code and description, presentation, storage conditions, manufacturer information and data on label.</p>
<p><b>Labelling</b><br />
On product’s box: product code, batch number, manufacture and expiration date, bar code and datamatrix code.</p>
<p><b>Possible target markets:</b><br />
Healthcare, Pharmaceutical and Medical industries.</p>
<p><b>Other important information.</b><br />
Read product’s instructions for use thoroughly before use.</p>
<p><b>Precautions</b><br />
Handle with gloves at all times.<br />
Do not open until use.<br />
Do not reuse.<br />
Do not re-incubate.<br />
Do not swab surfaces that have not been subjected to a cleaning process or visibly contaminated areas.<br />
Avoid touching the absorbent part of the swab or the inside of the device with your hands. Use gloves, a mask and other hygiene measures.<br />
Do not freeze.<br />
Do not use Chemdye® SWE swabs on any device other than</p>
<p>Chemdye® PRO 1 ENDO.<br />
High concentrations of alkaline detergents may cause false-negative results in some cases. Oxidizing disinfectants (such as hydrogen peroxide or peracetic acid) may cause a false-positive color change reaction. Although Chemdye® PRO1 ENDO has high sensitivity, its intended use corresponds to the monitoring of channels after the cleaning process, so the test result is not evidence that the device is sterile.</p>
<p>The post <a href="https://terragene.com/product/swe-1-7-hygiene-indicator-chemdye-for-use-with-pro1-endo/">High absorption swabs Chemdye® for use with PRO1 ENDO</a> first appeared on <a href="https://terragene.com">Terragene</a>.</p>]]></content:encoded>
					
					<wfw:commentRss>https://terragene.com/product/swe-1-7-hygiene-indicator-chemdye-for-use-with-pro1-endo/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
			</item>