<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>Chemical strips - Terragene</title>
	<atom:link href="https://terragene.com/product-tag/chemical-strips/feed/" rel="self" type="application/rss+xml" />
	<link>https://terragene.com</link>
	<description>Biotechnology Company</description>
	<lastBuildDate>Fri, 16 Jan 2026 12:36:25 +0000</lastBuildDate>
	<language>en</language>
	<sy:updatePeriod>
	hourly	</sy:updatePeriod>
	<sy:updateFrequency>
	1	</sy:updateFrequency>
	<generator>https://wordpress.org/?v=6.9.4</generator>

<image>
	<url>https://terragene.com/wp-content/uploads/2020/12/cropped-FAVICON-TERRAGENE-AZUL-Rev.1-32x32.png</url>
	<title>Chemical strips - Terragene</title>
	<link>https://terragene.com</link>
	<width>32</width>
	<height>32</height>
</image> 
	<item>
		<title>Multi-variable chemical indicator for Steam</title>
		<link>https://terragene.com/product/multi-variable-chemical-indicator-for-steam/</link>
					<comments>https://terragene.com/product/multi-variable-chemical-indicator-for-steam/#respond</comments>
		
		<dc:creator><![CDATA[Agustin Alvarez]]></dc:creator>
		<pubDate>Wed, 17 Mar 2021 12:45:18 +0000</pubDate>
				<guid isPermaLink="false">https://uvcindicators.com/?post_type=product&#038;p=2884</guid>

					<description><![CDATA[<p>CD20 / Multi-variable Chemical Indicator, strips printed with reactive ink for Steam sterilization processes.</p>
<p>Chemdye® CD20 Multivariable Indicators have been designed to react to Steam sterilization processes within loads, ensuring an adequate control of the effectiveness of sterilization processes (temperature, time and steam quality).</p>
<p>Chemdye® CD20 Multivariable Indicators have been manufactured with an innovative ink tecnology, highly sensitive to steam quality and air presence within the load.</p>
<p>The purple ink was developed to turn to green when the process reaches the stated values of the critical process variables.</p>
<p>Multivariable indicators allow to rapidly detect whether the critical parameters of the sterilization process for which they have been designed to respond have been reached. Endpoint conditions: 121 °C, 15 minutes // 134 °C, 3.5 minutes.</p>
<p><strong>Instructions for use</strong></p>
<p>- Place a Chemdye® CD20 Multivariable Indicator within each package, bag or tray that will be sterilized by steam.</p>
<p>- In rigid containers place the indicator in every corner, or at least two diagonally opposite corners, to ensure that the sterilization agent has reached the most inaccessible areas.</p>
<p>- After completing the process, analyze results. The indicator must turn to the reference color for considering that the indicated conditions were met.</p>
<p>The post <a href="https://terragene.com/product/multi-variable-chemical-indicator-for-steam/">Multi-variable chemical indicator for Steam</a> first appeared on <a href="https://terragene.com">Terragene</a>.</p>]]></description>
										<content:encoded><![CDATA[<p>Terragene</p><p>The post <a href="https://terragene.com/product/multi-variable-chemical-indicator-for-steam/">Multi-variable chemical indicator for Steam</a> first appeared on <a href="https://terragene.com">Terragene</a>.</p>]]></content:encoded>
					
					<wfw:commentRss>https://terragene.com/product/multi-variable-chemical-indicator-for-steam/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
			</item>
		<item>
		<title>Multi-variable chemical indicator for Steam</title>
		<link>https://terragene.com/product/multi-variable-chemical-indicator-for-steam-4/</link>
					<comments>https://terragene.com/product/multi-variable-chemical-indicator-for-steam-4/#respond</comments>
		
		<dc:creator><![CDATA[Agustin Alvarez]]></dc:creator>
		<pubDate>Wed, 17 Mar 2021 12:45:18 +0000</pubDate>
				<guid isPermaLink="false">https://uvcindicators.com/?post_type=product&#038;p=2896</guid>

					<description><![CDATA[<p>Multi-variable Chemical Indicator printed with reactive ink for Steam sterilization processes.</p>
<p>Chemdye® CD29 Multivariable Process Indicators (Type 4 according to ISO 11140-1:2014 standard) are single-use chemical indicators that consist of one-side laminated punched paper double strips printed with indicator ink. These indicators have been designed to monitor Steam sterilization processes within loads, ensuring an adequate exposure to the sterilizing agent during the sterilization process and allowing to distinguish between processed and unprocessed items.</p>
<p>Innovative highly sensitive yellow ink was developed to turn to dark brown/black when the indicator is exposed to Steam considering the critical process variables which provides additional quality assurance. Endpoint condition: 121 °C, 15 minutes; 134 °C, 3.5 minutes. Indicators 100 % free of toxic heavy metals. Please review the instructions for use for applicable cycles in your country</p>
<p><strong>Instructions for Use</strong></p>
<p>1. Place a Chemdye® CD29 Multivariable Process Indicator within each package, bag or tray that will be sterilized by Steam. In rigid containers, place the indicator in every corner, or at least two diagonally opposite corners, to ensure that the sterilization agent has reached the most inaccessible areas.</p>
<p>2. Perform the sterilization cycle.</p>
<p>3. After the sterilization process has finished, remove the indicators from the sterilizer and analyze the results. For all the chemical indicators exposed to Steam, the ink must turn to the dark brown/black reference color when the sterilization parameters are reached. For reference color, please refer to Result Reference Guide.</p>
<p>The post <a href="https://terragene.com/product/multi-variable-chemical-indicator-for-steam-4/">Multi-variable chemical indicator for Steam</a> first appeared on <a href="https://terragene.com">Terragene</a>.</p>]]></description>
										<content:encoded><![CDATA[<p>Multi-variable Chemical Indicator printed with reactive ink for Steam sterilization processes.</p>
<p>Chemdye® CD29 Multivariable Process Indicators (Type 4 according to ISO 11140-1:2014 standard) are single-use chemical indicators that consist of one-side laminated punched paper double strips printed with indicator ink. These indicators have been designed to monitor Steam sterilization processes within loads, ensuring an adequate exposure to the sterilizing agent during the sterilization process and allowing to distinguish between processed and unprocessed items.</p>
<p>Innovative highly sensitive yellow ink was developed to turn to dark brown/black when the indicator is exposed to Steam considering the critical process variables which provides additional quality assurance. Endpoint condition: 121 °C, 15 minutes; 134 °C, 3.5 minutes. Indicators 100 % free of toxic heavy metals. Please review the instructions for use for applicable cycles in your country</p>
<p><strong>Instructions for Use</strong></p>
<p>1. Place a Chemdye® CD29 Multivariable Process Indicator within each package, bag or tray that will be sterilized by Steam. In rigid containers, place the indicator in every corner, or at least two diagonally opposite corners, to ensure that the sterilization agent has reached the most inaccessible areas.</p>
<p>2. Perform the sterilization cycle.</p>
<p>3. After the sterilization process has finished, remove the indicators from the sterilizer and analyze the results. For all the chemical indicators exposed to Steam, the ink must turn to the dark brown/black reference color when the sterilization parameters are reached. For reference color, please refer to Result Reference Guide.</p>
<p>The post <a href="https://terragene.com/product/multi-variable-chemical-indicator-for-steam-4/">Multi-variable chemical indicator for Steam</a> first appeared on <a href="https://terragene.com">Terragene</a>.</p>]]></content:encoded>
					
					<wfw:commentRss>https://terragene.com/product/multi-variable-chemical-indicator-for-steam-4/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
			</item>
		<item>
		<title>Multi-variable chemical indicator for Dry Heat</title>
		<link>https://terragene.com/product/multi-variable-chemical-indicator-for-dry-heat/</link>
					<comments>https://terragene.com/product/multi-variable-chemical-indicator-for-dry-heat/#respond</comments>
		
		<dc:creator><![CDATA[Agustin Alvarez]]></dc:creator>
		<pubDate>Wed, 17 Mar 2021 12:45:18 +0000</pubDate>
				<guid isPermaLink="false">https://uvcindicators.com/?post_type=product&#038;p=2898</guid>

					<description><![CDATA[<p>CD30 / Multi-variable Chemical Indicator strip printed with reactive ink for Dry Heat sterilization processes.</p>
<p>Chemdye® Multivariable Indicators are designed to react to Dry Heat sterilization processes within loads, ensuring an adequate control of the effectiveness of sterilization processes (temperature and time).</p>
<p>Dark blue ink was developed to turn to brown when the process reaches the selected variables. Multivariable indicators allow to rapidly detect whether the critical parameters of the sterilization process for which they have been designed to respond have been reached.</p>
<p><strong>Indications for use</strong></p>
<p>Use Chemdye® Multivariable Indicators for monitoring Dry Heat sterilization processes. Endpoint conditions: 160 °C, 40 minutes // 180 °C, 20 minutes.</p>
<p>The post <a href="https://terragene.com/product/multi-variable-chemical-indicator-for-dry-heat/">Multi-variable chemical indicator for Dry Heat</a> first appeared on <a href="https://terragene.com">Terragene</a>.</p>]]></description>
										<content:encoded><![CDATA[<p>CD30 / Multi-variable Chemical Indicator strip printed with reactive ink for Dry Heat sterilization processes.</p>
<p>Chemdye® Multivariable Indicators are designed to react to Dry Heat sterilization processes within loads, ensuring an adequate control of the effectiveness of sterilization processes (temperature and time).</p>
<p>Dark blue ink was developed to turn to brown when the process reaches the selected variables. Multivariable indicators allow to rapidly detect whether the critical parameters of the sterilization process for which they have been designed to respond have been reached.</p>
<p><strong>Indications for use</strong></p>
<p>Use Chemdye® Multivariable Indicators for monitoring Dry Heat sterilization processes. Endpoint conditions: 160 °C, 40 minutes // 180 °C, 20 minutes.</p>
<p>The post <a href="https://terragene.com/product/multi-variable-chemical-indicator-for-dry-heat/">Multi-variable chemical indicator for Dry Heat</a> first appeared on <a href="https://terragene.com">Terragene</a>.</p>]]></content:encoded>
					
					<wfw:commentRss>https://terragene.com/product/multi-variable-chemical-indicator-for-dry-heat/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
			</item>
		<item>
		<title>Chemical indicator for Hydrogen Peroxide</title>
		<link>https://terragene.com/product/chemical-indicator-for-hydrogen-peroxide/</link>
					<comments>https://terragene.com/product/chemical-indicator-for-hydrogen-peroxide/#respond</comments>
		
		<dc:creator><![CDATA[Agustin Alvarez]]></dc:creator>
		<pubDate>Wed, 17 Mar 2021 12:44:55 +0000</pubDate>
				<guid isPermaLink="false">https://uvcindicators.com/?post_type=product&#038;p=2850</guid>

					<description><![CDATA[<p>CD40 / Multi-variable Chemical Indicator, strips printed with reactive ink for Plasma or Vaporized Hydrogen Peroxide sterilization processes.</p>
<p>FDA cleared</p>
<p>Control of plasma or vaporized H2O2 sterilization processes. Conditions: 6 minutes, 50 °C, 2,3 mg/l H2O2.</p>
<p>Please review the instructions for use for applicable cycles in your country</p>
<p><strong>Characteristics</strong></p>
<p>-Type 4 Chemical Indicator (according to ISO 11140-1).</p>
<p>-Strips printed with indicator ink.</p>
<p>-Size: 105 x 18 mm (approximate).</p>
<p>-Initial color: Purple.</p>
<p>-Final color: Green.</p>
<p>-100 % Toxic Heavy Metals free.</p>
<p><strong>Instructions for Use</strong></p>
<p>1.Place a Chemdye® CD40 Multivariable Process Indicator within each package, bag or tray that will be sterilized by Plasma or Vaporized Hydrogen Peroxide. In rigid containers, place the indicator in every corner, or at least two diagonally opposite corners, to ensure that the sterilization agent has reached the most inaccessible areas.</p>
<p>2.Perform the sterilization cycle.</p>
<p>3.After the sterilization process has finished, remove the indicators from the sterilizer and analyze the results. For all the chemical indicators exposed to Plasma or Vaporized Hydrogen Peroxide, the ink must turn to the green or lighter reference color when the sterilization parameters are reached.</p>
<p>The post <a href="https://terragene.com/product/chemical-indicator-for-hydrogen-peroxide/">Chemical indicator for Hydrogen Peroxide</a> first appeared on <a href="https://terragene.com">Terragene</a>.</p>]]></description>
										<content:encoded><![CDATA[<p>Terragene</p><p>The post <a href="https://terragene.com/product/chemical-indicator-for-hydrogen-peroxide/">Chemical indicator for Hydrogen Peroxide</a> first appeared on <a href="https://terragene.com">Terragene</a>.</p>]]></content:encoded>
					
					<wfw:commentRss>https://terragene.com/product/chemical-indicator-for-hydrogen-peroxide/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
			</item>
	</channel>
</rss>