<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>Process Challenge Device - Terragene</title>
	<atom:link href="https://terragene.com/product-category/process-challenge-device/feed/" rel="self" type="application/rss+xml" />
	<link>https://terragene.com</link>
	<description>Biotechnology Company</description>
	<lastBuildDate>Thu, 12 Mar 2026 18:50:20 +0000</lastBuildDate>
	<language>en</language>
	<sy:updatePeriod>
	hourly	</sy:updatePeriod>
	<sy:updateFrequency>
	1	</sy:updateFrequency>
	<generator>https://wordpress.org/?v=6.9.4</generator>

<image>
	<url>https://terragene.com/wp-content/uploads/2020/12/cropped-FAVICON-TERRAGENE-AZUL-Rev.1-32x32.png</url>
	<title>Process Challenge Device - Terragene</title>
	<link>https://terragene.com</link>
	<width>32</width>
	<height>32</height>
</image> 
	<item>
		<title>7 sec Steam Test Pack Kit (with moving front integrator) &#8211; Photon</title>
		<link>https://terragene.com/product/7-sec-steam-test-pack-with-moving-front-integrator/</link>
					<comments>https://terragene.com/product/7-sec-steam-test-pack-with-moving-front-integrator/#respond</comments>
		
		<dc:creator><![CDATA[Agustin Alvarez]]></dc:creator>
		<pubDate>Thu, 20 Jan 2022 16:19:53 +0000</pubDate>
				<guid isPermaLink="false">https://terragene.com/?post_type=product&#038;p=23877</guid>

					<description><![CDATA[<p>Process Challenge Device for Steam sterilization processes.</p>
<p><strong>Usage</strong></p>
<p>For routine load release, especially for loads containing implants. For routine sterilizer monitoring. For periodic validation of the sterilizer (after installation, repair, relocation).</p>
<p>Detects inadequate air removal and steam penetration in dynamic- airremoval (pre-vacuum) and gravity displacement, steam autoclaves between 132-135 ºC.</p>
<p><strong>Applicable regulation </strong></p>
<p>Designed under Quality Management System standards ISO 13485:2016/NS-EN ISO 13485:2016. ISO 11140-1:2014, ISO 11138-1:2017, ISO 11138-3:2017, ANSI/AAMI ST79.</p>
<p><strong>Authorization</strong></p>
<p>ANMAT (Argentinean National Administration of Drugs, Food and Medical Devices) PM 1614-4.</p>
<p><strong>Classification </strong></p>
<p>Class 1, according to risk (ANMAT).</p>
<p><strong>Characteristics</strong></p>
<p>The kit consist of:<br />
- PCD225-C: Porous cards system holding:<br />
A Self-contained Biological Indicator Bionova® BT225 (Photon).<br />
A Type 5 chemical indicator Integron® IT26-C (moving-front<br />
integrator).<br />
A self-adhesive Record Card, PCDBI-C-RC, where data on sterilization<br />
cycle may be written.<br />
- Self-contained Biological Indicator Bionova® BT225 (to be used as a<br />
positive control)</p>
<p><strong>Process Indicator:</strong></p>
<p>Initial color: light blue<br />
Final color: dark grey or black</p>
<p><strong>IT26-C Integrator Indicator (within the challenge device):</strong> The migration is visible through a zone marked ACCEPT or REJECT, thus indicating whether sterilization conditions were met. Integration condition is calibrated against the kill time of a 106 G. stearothermophilus ATCC® (ATCC is <span style="font-weight: 400;">a registered trademark of American Type Culture Collection)</span> 7953 spores’ population, calculated in BIER (Biological Indicator Evaluator Resistometer). Conditions: saturated steam at 121 °C, 128 °C, 135 °C.</p>
<p><strong>BT225 (Photon) the Instant Self-contained Biological Indicator (within the challenge device): </strong>≥ 106 G. stearothermophilus ATCC® (<span style="font-weight: 400;">ATCC is a registered trademark of American Type Culture Collection) </span>7953 spores per vial in paper carrier. Glass ampoule with growth indicator medium. Label with chemical indicator line printed with Steam reactive ink (Color change: pink to brown).</p>
<p><strong>Final results:</strong> instant fluorescence readout (7 second readout) after incubation at 60 °C (sensitivity ≥ 97%). A visual confirmation of the result is optional (color change of the medium caused by pH change) and can be made after incubation at 60 °C for 48 hours and/or for 7 days.</p>
<p><strong>NOTE:</strong> If sterilization process was not successful, indicator medium will turn yellow after incubation, thus indicating the presence of living G. stearothermophilus spores. If sterilization process was successful, indicator medium will remain purple after incubation. Environmental conditions during manufacture T= 15-30 °C, RH= 30-80 %.</p>
<p><strong>Storage conditions</strong></p>
<p>T= 10-30 °C, RH= 30-80 %, keep out of direct ligh Transport conditions Storage conditions should be strictly followed. Carry in closed and reinforced boxes in order to avoid damages. The transport of this product does not represent a risk for health.</p>
<p><strong>Shelf life</strong></p>
<p>18 months.</p>
<p><strong>Packing</strong></p>
<p>Presentations: 25 PCD225-C + 25 BT225 Biological Indicators per box.</p>
<p>25 PCD225-C + 5 BT225 Biological Indicators per box.</p>
<p>16 PCD225-C + 4 BT225 Biological Indicators per box. Packing information: product code and description, regulation, conditions for use, instructions for use, storage conditions, manufacturer information and data on box´s label.</p>
<p>Labelling</p>
<p>On product’s packing: product code and description, presentation, regulation, batch number, batch number of the Self-contained Biological Indicator, manufacture and expiration date, bar code and datamatrix code.</p>
<p><strong>Possible target markets</strong></p>
<p>Healthcare, Food, Pharmaceutical and Medical Industries.</p>
<p><strong>Other important information </strong></p>
<p>Read product’s instructions for use thoroughly before use.</p>
<p><strong>Precautions</strong></p>
<p>Do not store the product near sterilizing agents.</p>
<p>Do not expose this product to EO, Dry Heat, Radiation or any sterilization process other than Steam.</p>
<p>The post <a href="https://terragene.com/product/7-sec-steam-test-pack-with-moving-front-integrator/">7 sec Steam Test Pack Kit (with moving front integrator) – Photon</a> first appeared on <a href="https://terragene.com">Terragene</a>.</p>]]></description>
										<content:encoded><![CDATA[<p>Process Challenge Device for Steam sterilization processes.</p>
<p><strong>Usage</strong></p>
<p>For routine load release, especially for loads containing implants. For routine sterilizer monitoring. For periodic validation of the sterilizer (after installation, repair, relocation).</p>
<p>Detects inadequate air removal and steam penetration in dynamic- airremoval (pre-vacuum) and gravity displacement, steam autoclaves between 132-135 ºC.</p>
<p><strong>Applicable regulation </strong></p>
<p>Designed under Quality Management System standards ISO 13485:2016/NS-EN ISO 13485:2016. ISO 11140-1:2014, ISO 11138-1:2017, ISO 11138-3:2017, ANSI/AAMI ST79.</p>
<p><strong>Authorization</strong></p>
<p>ANMAT (Argentinean National Administration of Drugs, Food and Medical Devices) PM 1614-4.</p>
<p><strong>Classification </strong></p>
<p>Class 1, according to risk (ANMAT).</p>
<p><strong>Characteristics</strong></p>
<p>The kit consist of:<br />
- PCD225-C: Porous cards system holding:<br />
A Self-contained Biological Indicator Bionova® BT225 (Photon).<br />
A Type 5 chemical indicator Integron® IT26-C (moving-front<br />
integrator).<br />
A self-adhesive Record Card, PCDBI-C-RC, where data on sterilization<br />
cycle may be written.<br />
- Self-contained Biological Indicator Bionova® BT225 (to be used as a<br />
positive control)</p>
<p><strong>Process Indicator:</strong></p>
<p>Initial color: light blue<br />
Final color: dark grey or black</p>
<p><strong>IT26-C Integrator Indicator (within the challenge device):</strong> The migration is visible through a zone marked ACCEPT or REJECT, thus indicating whether sterilization conditions were met. Integration condition is calibrated against the kill time of a 106 G. stearothermophilus ATCC® (ATCC is <span style="font-weight: 400;">a registered trademark of American Type Culture Collection)</span> 7953 spores’ population, calculated in BIER (Biological Indicator Evaluator Resistometer). Conditions: saturated steam at 121 °C, 128 °C, 135 °C.</p>
<p><strong>BT225 (Photon) the Instant Self-contained Biological Indicator (within the challenge device): </strong>≥ 106 G. stearothermophilus ATCC® (<span style="font-weight: 400;">ATCC is a registered trademark of American Type Culture Collection) </span>7953 spores per vial in paper carrier. Glass ampoule with growth indicator medium. Label with chemical indicator line printed with Steam reactive ink (Color change: pink to brown).</p>
<p><strong>Final results:</strong> instant fluorescence readout (7 second readout) after incubation at 60 °C (sensitivity ≥ 97%). A visual confirmation of the result is optional (color change of the medium caused by pH change) and can be made after incubation at 60 °C for 48 hours and/or for 7 days.</p>
<p><strong>NOTE:</strong> If sterilization process was not successful, indicator medium will turn yellow after incubation, thus indicating the presence of living G. stearothermophilus spores. If sterilization process was successful, indicator medium will remain purple after incubation. Environmental conditions during manufacture T= 15-30 °C, RH= 30-80 %.</p>
<p><strong>Storage conditions</strong></p>
<p>T= 10-30 °C, RH= 30-80 %, keep out of direct ligh Transport conditions Storage conditions should be strictly followed. Carry in closed and reinforced boxes in order to avoid damages. The transport of this product does not represent a risk for health.</p>
<p><strong>Shelf life</strong></p>
<p>18 months.</p>
<p><strong>Packing</strong></p>
<p>Presentations: 25 PCD225-C + 25 BT225 Biological Indicators per box.</p>
<p>25 PCD225-C + 5 BT225 Biological Indicators per box.</p>
<p>16 PCD225-C + 4 BT225 Biological Indicators per box. Packing information: product code and description, regulation, conditions for use, instructions for use, storage conditions, manufacturer information and data on box´s label.</p>
<p>Labelling</p>
<p>On product’s packing: product code and description, presentation, regulation, batch number, batch number of the Self-contained Biological Indicator, manufacture and expiration date, bar code and datamatrix code.</p>
<p><strong>Possible target markets</strong></p>
<p>Healthcare, Food, Pharmaceutical and Medical Industries.</p>
<p><strong>Other important information </strong></p>
<p>Read product’s instructions for use thoroughly before use.</p>
<p><strong>Precautions</strong></p>
<p>Do not store the product near sterilizing agents.</p>
<p>Do not expose this product to EO, Dry Heat, Radiation or any sterilization process other than Steam.</p>
<p>The post <a href="https://terragene.com/product/7-sec-steam-test-pack-with-moving-front-integrator/">7 sec Steam Test Pack Kit (with moving front integrator) – Photon</a> first appeared on <a href="https://terragene.com">Terragene</a>.</p>]]></content:encoded>
					
					<wfw:commentRss>https://terragene.com/product/7-sec-steam-test-pack-with-moving-front-integrator/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
			</item>
		<item>
		<title>Steam Test Pack PCD Kit – 7 Second Readout</title>
		<link>https://terragene.com/product/steam-test-pack-pcd-kit-7-second-readout/</link>
					<comments>https://terragene.com/product/steam-test-pack-pcd-kit-7-second-readout/#respond</comments>
		
		<dc:creator><![CDATA[Agustin Alvarez]]></dc:creator>
		<pubDate>Wed, 11 Mar 2026 14:10:57 +0000</pubDate>
				<guid isPermaLink="false">https://terragene.com/?post_type=product&#038;p=66300</guid>

					<description><![CDATA[<p>The Steam Test Pack PCD Kit is a Process Challenge Device designed for routine load release, sterilizer monitoring, and validation of steam sterilization processes. Each kit includes a Bionova® BT225 self-contained biological indicator and a Type 5 chemical indicator, ensuring accurate detection of air removal and steam penetration. Read in the Photon Auto-Reader incubator with instant 7-second results, this kit provides reliable performance, ISO compliance, and is ideal for healthcare, pharmaceutical, and food industries.</p>
<p>The post <a href="https://terragene.com/product/steam-test-pack-pcd-kit-7-second-readout/">Steam Test Pack PCD Kit – 7 Second Readout</a> first appeared on <a href="https://terragene.com">Terragene</a>.</p>]]></description>
										<content:encoded><![CDATA[<p>The Steam Test Pack PCD Kit is a Process Challenge Device designed for routine load release, sterilizer monitoring, and validation of steam sterilization processes. Each kit includes a Bionova® BT225 self-contained biological indicator and a Type 5 chemical indicator, ensuring accurate detection of air removal and steam penetration. Read in the Photon Auto-Reader incubator with instant 7-second results, this kit provides reliable performance, ISO compliance, and is ideal for healthcare, pharmaceutical, and food industries.</p>
<p>The post <a href="https://terragene.com/product/steam-test-pack-pcd-kit-7-second-readout/">Steam Test Pack PCD Kit – 7 Second Readout</a> first appeared on <a href="https://terragene.com">Terragene</a>.</p>]]></content:encoded>
					
					<wfw:commentRss>https://terragene.com/product/steam-test-pack-pcd-kit-7-second-readout/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
			</item>
		<item>
		<title>20min Steam Test Pack PCD Kit (with moving front integrator)</title>
		<link>https://terragene.com/product/20min-steam-test-pack-pcd-kit-with-moving-front-integrator/</link>
					<comments>https://terragene.com/product/20min-steam-test-pack-pcd-kit-with-moving-front-integrator/#respond</comments>
		
		<dc:creator><![CDATA[Agustin Alvarez]]></dc:creator>
		<pubDate>Fri, 19 Mar 2021 12:45:39 +0000</pubDate>
				<guid isPermaLink="false">https://uvcindicators.com/?post_type=product&#038;p=3369</guid>

					<description><![CDATA[<p>KPCD224-C / Test Pack PCD Kit. Process Challenge Device for Steam sterilization processes with moving-front Type 5 Integrator and Bionova® Ultra Rapid Self-contained Biological Indicator BT224, plus Bionova® BT224 Biological Indicators Positive Control. Class 5 spores per strip.</p>
<p>FDA cleared</p>
<p>For routine load release, especially for loads containing implants. For routine sterilizer monitoring. For periodic validation of the sterilizer (after installation, repair, relocation).</p>
<p>Detects inadequate air removal and steam penetration in dynamic- airremoval (pre-vacuum) and gravity displacement, steam autoclaves between 132-135 ºC.</p>
<p>Please review the instructions for use for applicable cycles in your country</p>
<p><strong>Characteristics</strong></p>
<p>The kit consist of:</p>
<p>- PCD224-C: Porous cards system holding:</p>
<p>A Self-contained Biological Indicator Bionova® BT224.A Type 5 chemical indicator Integron® IT26-C (moving-front integrator). A self-adhesive Record Card, PCDBI-C-RC, where data on sterilization cycle may be written.</p>
<p>- Self-contained Biological Indicator Bionova® BT224 (to be used as a</p>
<p>positive control)</p>
<p>Process Indicator:</p>
<p>-Initial color: blue.</p>
<p>-Final color: dark grey or black.</p>
<p>IT26-C Integrator Indicator (within the challenge device): The migration is visible through a zone marked ACCEPT or REJECT, thus indicating whether sterilization conditions were met.</p>
<p>Integration condition is calibrated against the kill time of a 106 G. stearothermophilus ATCC 7953 spore population, calculated in BIER (Biological Indicator Evaluator Resistometer). Conditions: saturated steam at 121 ºC, 128 ºC, 135 ºC.</p>
<p>BT224 Self-contained Ultra Rapid Biological Indicator (within the challenge device): 106 G. stearothermophilus ATCC 7953 spores per vial in paper carrier. Glass ampoule with growth indicator medium. Label with chemical indicator line printed with Steam reactive ink (Color change: pink to brown)</p>
<p>Final results: by fluorescence after incubation for 20 minutes at 60 ºC (sensitivity 97%). An optional visual pH color change confirmation could be made after 48 hours of incubation. A 7-day readout is optional to confirm 20-minutes results by color change.</p>
<p>NOTE: If sterilization process was not successful, indicator medium will turn yellow after incubation, thus indicating the presence of living G. stearothermophilus spores. If sterilization process was successful, indicator medium will remain purple after incubation.</p>
<p>The post <a href="https://terragene.com/product/20min-steam-test-pack-pcd-kit-with-moving-front-integrator/">20min Steam Test Pack PCD Kit (with moving front integrator)</a> first appeared on <a href="https://terragene.com">Terragene</a>.</p>]]></description>
										<content:encoded><![CDATA[<p>KPCD224-C / Test Pack PCD Kit. Process Challenge Device for Steam sterilization processes with moving-front Type 5 Integrator and Bionova® Ultra Rapid Self-contained Biological Indicator BT224, plus Bionova® BT224 Biological Indicators Positive Control. Class 5 spores per strip.</p>
<p>FDA cleared</p>
<p>For routine load release, especially for loads containing implants. For routine sterilizer monitoring. For periodic validation of the sterilizer (after installation, repair, relocation).</p>
<p>Detects inadequate air removal and steam penetration in dynamic- airremoval (pre-vacuum) and gravity displacement, steam autoclaves between 132-135 ºC.</p>
<p>Please review the instructions for use for applicable cycles in your country</p>
<p><strong>Characteristics</strong></p>
<p>The kit consist of:</p>
<p>- PCD224-C: Porous cards system holding:</p>
<p>A Self-contained Biological Indicator Bionova® BT224.A Type 5 chemical indicator Integron® IT26-C (moving-front integrator). A self-adhesive Record Card, PCDBI-C-RC, where data on sterilization cycle may be written.</p>
<p>- Self-contained Biological Indicator Bionova® BT224 (to be used as a</p>
<p>positive control)</p>
<p>Process Indicator:</p>
<p>-Initial color: blue.</p>
<p>-Final color: dark grey or black.</p>
<p>IT26-C Integrator Indicator (within the challenge device): The migration is visible through a zone marked ACCEPT or REJECT, thus indicating whether sterilization conditions were met.</p>
<p>Integration condition is calibrated against the kill time of a 106 G. stearothermophilus ATCC 7953 spore population, calculated in BIER (Biological Indicator Evaluator Resistometer). Conditions: saturated steam at 121 ºC, 128 ºC, 135 ºC.</p>
<p>BT224 Self-contained Ultra Rapid Biological Indicator (within the challenge device): 106 G. stearothermophilus ATCC 7953 spores per vial in paper carrier. Glass ampoule with growth indicator medium. Label with chemical indicator line printed with Steam reactive ink (Color change: pink to brown)</p>
<p>Final results: by fluorescence after incubation for 20 minutes at 60 ºC (sensitivity 97%). An optional visual pH color change confirmation could be made after 48 hours of incubation. A 7-day readout is optional to confirm 20-minutes results by color change.</p>
<p>NOTE: If sterilization process was not successful, indicator medium will turn yellow after incubation, thus indicating the presence of living G. stearothermophilus spores. If sterilization process was successful, indicator medium will remain purple after incubation.</p>
<p>The post <a href="https://terragene.com/product/20min-steam-test-pack-pcd-kit-with-moving-front-integrator/">20min Steam Test Pack PCD Kit (with moving front integrator)</a> first appeared on <a href="https://terragene.com">Terragene</a>.</p>]]></content:encoded>
					
					<wfw:commentRss>https://terragene.com/product/20min-steam-test-pack-pcd-kit-with-moving-front-integrator/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
			</item>
		<item>
		<title>20min Steam Test Pack PCD Kit (with one point integrator)</title>
		<link>https://terragene.com/product/20min-steam-test-pack-pcd-kit-with-one-point-integrator/</link>
					<comments>https://terragene.com/product/20min-steam-test-pack-pcd-kit-with-one-point-integrator/#respond</comments>
		
		<dc:creator><![CDATA[Agustin Alvarez]]></dc:creator>
		<pubDate>Fri, 19 Mar 2021 12:45:35 +0000</pubDate>
				<guid isPermaLink="false">https://uvcindicators.com/?post_type=product&#038;p=3367</guid>

					<description><![CDATA[<p>KPCD224-2 / Steam Test Pack PCD Kit. Process Challenge Device for Steam sterilization processes, with self-adhesive Type 5 Indicator(Turns from Purple to Green) and Bionova® Ultra Rapid Self-contained Biological Indicator BT224 plus Bionova® BT224 Biological Indicators Positive Control.</p>
<p>FDA cleared</p>
<p>For routine load release, especially for loads containing implants. For routine sterilizer monitoring. For periodic validation of the sterilizer (after installation, repair, relocation).</p>
<p>Detects inadequate air removal and steam penetration in dynamicair-removal (pre-vacuum) and gravity displacement, steam autoclaves between 132-135 ºC.</p>
<p>Please review the instructions for use for applicable cycles in your country</p>
<p><strong>Characteristics</strong></p>
<p>The kit consist of:</p>
<p>- PCD224-2: Porous cards system holding:</p>
<p>A Self-contained Biological Indicator Bionova® BT224. A Type 5 chemical indicator. A self-adhesive Record Card, PCDBI-2-RC, where data on sterilization cycle may be written. Two possibilities for documentation record: the whole Record Card can be adhered, or alternatively, only the area containing the indicator may be recorded.</p>
<p>- Self-contained Biological Indicator Bionova® BT224 (to be used as</p>
<p>a positive control)</p>
<p>Process Indicator:</p>
<p>-Initial color: blue.</p>
<p>-Final color: dark grey or black.</p>
<p>PCDBI-2-RC Integrator Indicator (within the challenge device):</p>
<p>-Initial color: purple.</p>
<p>-Final color: green.</p>
<p>100 % Toxic Heavy Metals free.</p>
<p>Integration condition is calibrated against the kill time of a 106 G. stearothermophilus ATCC 7953 spore population, calculated in BIER (Biological Indicator Evaluator Resistometer). Conditions: saturated steam at 121 ºC, 128 ºC, 135 ºC. Rev. 2 / 07.2020 PÃ¡gina 2 / 8</p>
<p>Infection Control Division &#124; Chemical Indicators EN BT224 Self-contained Ultra Rapid Biological Indicator (within the challenge device): 106 G. stearothermophilus ATCC 7953 spores per vial in paper carrier. Glass ampoule with growth indicator medium. Label with chemical indicator line printed with Steam reactive ink (Color change: pink to brown).</p>
<p>Final results: by fluorescence after incubation for 20 minutes at 60 ºC (sensitivity 97%). An optional visual pH color change confirmation could be made after 48 hours of incubation.</p>
<p>A 7-day readout is optional to confirm 20-minutes results by color change.</p>
<p>NOTE: If sterilization process was not successful, indicator medium will turn yellow after incubation, thus indicating the presence of living G. stearothermophilus spores. If sterilization process was successful, indicator medium will remain purple after incubation.</p>
<p>The post <a href="https://terragene.com/product/20min-steam-test-pack-pcd-kit-with-one-point-integrator/">20min Steam Test Pack PCD Kit (with one point integrator)</a> first appeared on <a href="https://terragene.com">Terragene</a>.</p>]]></description>
										<content:encoded><![CDATA[<p>KPCD224-2 / Steam Test Pack PCD Kit. Process Challenge Device for Steam sterilization processes, with self-adhesive Type 5 Indicator(Turns from Purple to Green) and Bionova® Ultra Rapid Self-contained Biological Indicator BT224 plus Bionova® BT224 Biological Indicators Positive Control.</p>
<p>FDA cleared</p>
<p>For routine load release, especially for loads containing implants. For routine sterilizer monitoring. For periodic validation of the sterilizer (after installation, repair, relocation).</p>
<p>Detects inadequate air removal and steam penetration in dynamicair-removal (pre-vacuum) and gravity displacement, steam autoclaves between 132-135 ºC.</p>
<p>Please review the instructions for use for applicable cycles in your country</p>
<p><strong>Characteristics</strong></p>
<p>The kit consist of:</p>
<p>- PCD224-2: Porous cards system holding:</p>
<p>A Self-contained Biological Indicator Bionova® BT224. A Type 5 chemical indicator. A self-adhesive Record Card, PCDBI-2-RC, where data on sterilization cycle may be written. Two possibilities for documentation record: the whole Record Card can be adhered, or alternatively, only the area containing the indicator may be recorded.</p>
<p>- Self-contained Biological Indicator Bionova® BT224 (to be used as</p>
<p>a positive control)</p>
<p>Process Indicator:</p>
<p>-Initial color: blue.</p>
<p>-Final color: dark grey or black.</p>
<p>PCDBI-2-RC Integrator Indicator (within the challenge device):</p>
<p>-Initial color: purple.</p>
<p>-Final color: green.</p>
<p>100 % Toxic Heavy Metals free.</p>
<p>Integration condition is calibrated against the kill time of a 106 G. stearothermophilus ATCC 7953 spore population, calculated in BIER (Biological Indicator Evaluator Resistometer). Conditions: saturated steam at 121 ºC, 128 ºC, 135 ºC. Rev. 2 / 07.2020 PÃ¡gina 2 / 8</p>
<p>Infection Control Division &#124; Chemical Indicators EN BT224 Self-contained Ultra Rapid Biological Indicator (within the challenge device): 106 G. stearothermophilus ATCC 7953 spores per vial in paper carrier. Glass ampoule with growth indicator medium. Label with chemical indicator line printed with Steam reactive ink (Color change: pink to brown).</p>
<p>Final results: by fluorescence after incubation for 20 minutes at 60 ºC (sensitivity 97%). An optional visual pH color change confirmation could be made after 48 hours of incubation.</p>
<p>A 7-day readout is optional to confirm 20-minutes results by color change.</p>
<p>NOTE: If sterilization process was not successful, indicator medium will turn yellow after incubation, thus indicating the presence of living G. stearothermophilus spores. If sterilization process was successful, indicator medium will remain purple after incubation.</p>
<p>The post <a href="https://terragene.com/product/20min-steam-test-pack-pcd-kit-with-one-point-integrator/">20min Steam Test Pack PCD Kit (with one point integrator)</a> first appeared on <a href="https://terragene.com">Terragene</a>.</p>]]></content:encoded>
					
					<wfw:commentRss>https://terragene.com/product/20min-steam-test-pack-pcd-kit-with-one-point-integrator/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
			</item>
	</channel>
</rss>